Dometic Waeco CombiPower 2012 Instructions De Montage page 90

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

_CombiPower_IA_DE-IT.book Seite 90 Freitag, 21. Oktober 2011 8:10 20
Connecting the device
Parameter
Battery types a
Standard operating mode
With the "COMBI Power On"
setting, the device acts as a
charger and, when neces-
sary, as an inverter if there is
not enough power available
at the AC input.
With the "CHR Power On",
setting, the device only acts
as a charger. The inverter
function is deactivated.
I phase (bulk) charging
voltage
U0 phase (absorption)
charging voltage
U phase (floating) charging
voltage
90
Setting
Battery type I
Battery type II
Battery type III
Battery type IV
COMBI Power On
CHR Power on
Battery type I
Battery type II
12 V
24 V
12 V
14,4 V
28,8 V
14,4 V
14,4 V
28,8 V
14,25 V
13,5 V
27,0 V
13,8 V
Switch position
Battery type III
24 V
12 V
24 V
28,8 V
14,7 V
29,6 V
28,5 V
14,25 V
28,5 V
27.6 V
13.6 V
27,2 V
CombiPower
Battery type IV
(Customer)
12 V
24 V
14 – 15 V 28 – 30 V
14 – 15 V 28 – 30 V
13 – 14 V 26 – 28 V
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Waeco combipower 2024

Table des Matières