Dometic Waeco CombiPower 2012 Instructions De Montage page 71

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

_CombiPower_IA_DE-IT.book Seite 71 Freitag, 21. Oktober 2011 8:10 20
CombiPower
No. in
fig. 4,
Symbol
page 4
11
12
13
EN
Explanation/function
Jumper for activating or deactivating an external
switch:
 Jumper open: external switch function
deactivated
 Jumper inserted (factory setting): external switch
function activated
4-pin plug
 PIN 1: ALM (alarm- function)
not currently activated
 PIN 2: CTL
Depending on the jumper (fig. 4 11, page 4) the
device can be forcibly switched on or off with a
positive signal.
Jumper open:
CTL input voltage 5 – 60 Vg = ON
CTL input voltage 0 Vg = OFF
Jumper closed:
CTL input voltage 5 – 60 Vg = OFF
CTL input voltage 0 Vg = ON
 PIN 3: –ENB, PIN 4: –VCC
The device can be switched on and off using
these pins. No external voltage is required for
this. –ENB is connected via a switch to –VCC
(–VCC may not be connected to the negative
terminal of the battery.)
See fig. 6, page 5:
Switch closed = device ON
Switch open = device OFF
Note: If the device is switched on using this
function, it can be be switched off with the main
switch only.
Socket for remote control connection cable
Technical description
71

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Waeco combipower 2024

Table des Matières