Electrical Connexion; Control System - Astralpool 45637 Manuel D'installation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 5
THIS PRODUCT DOES NOT CONTAIN ANY ELEMENTS THAT CAN BE HANDLED, DISMANTLED OR REPLACED
BY THE USER. IT IS FORBIDDEN TO ACCESS INSIDE THE PRODUCT, OTHERWISE THE GUARANTEE OF THE

6. ELECTRICAL CONNEXION:

The projectors are supplied with a 2-wire 1.5mm2 Cu H07RNF cable.
This projector has been designed to operate only with a DMX control and with the DMX modulator from AstralPool. It
doesn't work with any other control system.

CONTROL SYSTEM

Do not install the 12V ~AC power lines of the lamps and modula-
tors near possible electrical interference of other signals.
It is necessary to install a modulator for each one of the existing
transformers in the installation.
The PAR56 DMX projector uses 3 DMX channels, one for each of
the 3 primary colours (red, green and blue). The configuration of
the DMX address should be performed from the modulator. One
modulator can control a maximum of 15 projectors. For indepen-
dent control, each projector should have its own transformer and
modulator. The different modulators should be assigned chan-
nels that do not overlap with other modulators.
See manual of the DMX modulator code 41107 for infor-
mation regarding how to assing DMX addresses to each
Mini LED projector or Quadraled and how to configure a
In installations with long lengths of power lines, it is re-
commended to lengthen the 230V ~AC line and install the
transformers near the projectors, and if necessary, lengthen
the 12V~AC line towards the DMX modulator, which con-
trols the projectors:
In accordance with the previous diagram, for correct ope-
ration, the cable sections should be suitable to the length
of the cable. The sections and lengths for a line in which
there is only one modulator, without any projector, are given
below:
Modulator Line (m)
150 - 300
0 - 50
For a line in which there are projectors, the sections are lengths are:
1 projector in the line
L. Projector (m)
LumiPlus 1.11
55 - 90
35 - 55
20 - 35
14 - 20
0 - 14
PRODUCT WILL BECOME INVALID.
system.
Section
2
2,5mm
Cu
2
1,5 mm
Cu
Section
LumiPlus 2.0
2
45 - 80
10 mm
2
30 - 45
6 mm
2
18 - 30
4 mm
2
10 - 18
2,5 mm
2
0 - 10
1,5 mm
DMX
PRESENCE
LED
INDICATOR
L. Projector (m)
LumiPlus 1.11
Cu
20 - 45
Cu
18 - 25
Cu
10 - 18
Cu
7 - 10
Cu
0 - 7
3
DMX LINE
TERMINATION
Projector line
Modulator line
2 projector in the line
Section
LumiPlus 2.0
20 - 40
10 mm
15 - 20
6 mm
8 - 15
4 mm
5 - 8
2,5 mm
0 - 5
1,5 mm
DMX ADRESS
INDICATOR
/SELECTOR
2
Cu
2
Cu
2
Cu
2
Cu
2
Cu

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

56002

Table des Matières