ENGLISH
Multigas table
DESCRIPTION
Lower Wobbe index (at 15°C-1013 mbar)
Net Calorifi c Value
Supply nominal pressure
Mynute Boiler Green E 25 B.S.I.
Supply minimum pressure
Burner: number of nozzles - diameter of nozzles - lenght
Diaphragm: number of holes - diameter of holes
Heating maximum gas capacity
DHW maximum gas capacity
Heating minimum gas capacity
DHW minimum gas capacity
Numbers of fan revolutions at slow start
Maximum number of fan revolutions (CH)
Maximum number of fan revolutions (DHW)
Minimum number of fan revolutions (CH)
Minimum number of fan revolutions (DHW)
Mynute Boiler Green E 32 B.S.I.
Supply minimum pressure
Burner: number of nozzles - diameter of nozzles - lenght
Diaphragm: number of holes - diameter of holes
Heating maximum gas capacity
DHW maximum gas capacity
Heating minimum gas capacity
DHW minimum gas capacity
Numbers of fan revolutions at slow start
Maximum number of fan revolutions (CH)
Maximum number of fan revolutions (DHW)
Minimum number of fan revolutions (CH)
Minimum number of fan revolutions (DHW)
18
Methane gas (G20)
MJ/m
3
S
MJ/m
3
S
MJ/KgS
mbar
(mm W.C.)
mbar
(mm W.C.)
n° - mm - mm
n° - mm
Sm
3
/h
kg/h
Sm
/h
3
kg/h
Sm
/h
3
kg/h
Sm
3
/h
kg/h
revs/min
revs/min
revs/min
revs/min
revs/min
mbar
(mm W.C.)
n° - mm - mm
n° - mm
Sm
/h
3
kg/h
Sm
3
/h
kg/h
Sm
3
/h
kg/h
Sm
/h
3
kg/h
revs/min
revs/min
revs/min
revs/min
revs/min
45,67
34,02
-
20
203,9
8
81,6
1 - 63 - 130
1 - 6,7
2,64
2,64
0,63
0,63
3.400
5.600
5.600
1.700
1.700
10
(102,0)
1 - 63 - 130
1 - 6,7
2,64
3,38
0,63
0,63
3.400
5.200
6.300
1.600
1.600
Propane (G31)
70,69
88
46,34
37
377,3
1 - 63 - 130
1 - 4,7
1,94
1,94
0,47
0,47
3.400
5.600
5.600
1.700
1.700
1 - 63 - 130
1 - 4,7
1,94
2,48
0,47
0,47
3.400
5.200
6.300
1.600
1.600