01.2 Û DESCRIPTION OF THE DEVICE
The user interface has been optimized with
the PIEZOSURGERY® touch making all the
functions readily available by integrating
them in the touch keyboard.
The PIEZOSURGERY® touch is a device that
uses ultrasonic piezoelectric technology to
generate mechanical microvibrations of the
inserts (from 20 to 60 μm), to effectively cut
mineralized tissues. This allows an efficient
and safe cutting which preserves the integrity
of the osteotomized surfaces.
01.3 Û RESPONSIBILITY WAIVER
The manufacturer Mectron disclaim any
liability, expressed or implied, and shall have
no responsibility for any direct, indirect or
other damages and personal injury arising
out in connection with any practice in the
use of the device and its accessories.
The manufacturer Mectron shall be under no
liability, expressed or implied, with respect to
any damages (personal injury and/or damage
to property) which might arise or be caused,
whether by the customer or by any of the
users of the product and its accessories, as
result of:
1 Use or procedures different than those
specified in the intended use of the
product;
2 The environmental conditions for the
preservation and storage of the device
are not compliant to the precautions
indicated in the Chapter 08 - TECHNICAL
DATA;
3 The device is not used in compliance
with all the instructions and precautions
described in this manual;
01 Û INTRODUCTION
The micrometric, ultrasonic vibrations of
the inserts provide greater precision and
a selective cutting action compared to
traditional methods such as drills or oscillating
saws (which act with macrovibrations),
therefore minimizing traumatic effect on soft
tissues .
The cavitation effect of the irrigating solution
helps to keep the operatory field blood-free.
This provides an optimal intra-operatory visual
control thus increasing safety, even in areas
that are anatomically most difficult to access.
4 The electrical system in the premises in
which the device is used is not compliant
to the norms in force and to the relative
precautions;
5 The assembly operations, extensions,
adjustments, updates, and repairs on the
device are performed by personnel not
authorized by Mectron;
6 Improper use, mistreatments, and/or
incorrect interventions;
7 Any and all attempts to tamper with or
modify the device, under any circumstance;
8 Use of non-original Mectron inserts that
entail a finite damage to the threading of
the handpiece, thus compromising correct
operation and causing risk of harm to the
patient:
9 Use of non-original Mectron inserts, used
in accordance to designed and tested
settings of Mectron original inserts. The
correct use of the settings is guaranteed
only with original Mectron inserts;
10 Lack of stock materials (handpiece, inserts,
wrenches) to be used in the event of device
stop due to fault or of inconveniences.