User manual - English

7.2.1 Cleaning the trough and the water level sensor:

(Also see service video capitel 10. or QR code)
6.
Switch off the machine at the
production
switch
"Produktion aus/off) and pull the
power plug(see capitel 2.3).
7.
Remove any ice remaining in
the
storage
container.
consumption must not come into
contact with the detergen.
8.
Adequately wet a clean sponge
or cloth with WESSAMAT special
cleaner and wipe the vertically
positioned
trough
through
the
storage
Repeat this procedure several times.
Keep wetting the sponge or cloth
with WESSAMAT special cleaner as
required. Allow a few minutes for the
special cleaner to act.
9.
Immerse the sponge or cloth in soap water and wipe the trough in order to neutralise the
special cleaner.
10. Clean the trough with clear water. Use a clean sponge or cloth. In case of persistent
soiling and deposits, this procedure (3.-5.) has to be repeated several times.
8.
Then clean the water level sensor. To do this, clean the three vertical sensors from below
with a normal sponge and thereby remove any limescale deposits
9.
Plug in the socket and put the machine back into operation at the production switch
("Production on / on" position). Then clean the storage container! See the following chapter
IMPORTANT:
Almost all cleaners contain acids which can cause corrosion. Therefore, all parts that
have been treated with cleaner must be rinsed thoroughly.
User-manual-HighLine-v.02
(Position
Ice
for
by
reaching
container.
Abb. 7.2.1: Darstellung Wanne und Wasserstandssonde
Produktions-
schalter
Wasser-
stands-
sonde
Wanne
Eis-
entnahme-
klappe
01/2021
54

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Highline w25 wHighline w55 leHighline w55 w

Table des Matières