Maintenance - Wessamat HighLine W25 LE Mode D'emploi

Highline
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

User manual - English

7.3 Maintenance

Regularly (approx. once a month) check the water supply tube and water drain tube for leaks
and adequate slope.
For water-cooled machines, the cooling water controller should be checked regularly for proper
function, because failure of the cooling water controller to close or close fully will lead to
increased water consumption and therefore higher operating costs. The condensation
temperature should be 30°C. With the machine switched off, no water should emerge from the
cooling water drain tube. Built-in machines may have to be removed for this purpose.
During reinstallation, prevent bending or kinking of the drain tube or the cooling water drain
tube, so that the water can drain freely!
The position of the limit switch must
also always be observed because it
can easily move. The following
illustration shows how the two limit
switches should be positioned.
The upper limit switch above -
perpendicular to the floor surface.
The lower limit switch below -
horizontal to the floor surface
IMPORTANT:
Other maintenance work should only be carried out by authorised WESSAMAT
service technician or service staff from authorised specialised dealers!
The frequency of maintenance depends on the place of installation and the water quality (e.g.
water hardness, contaminants etc.). Maintenance schedules therefore have to be determined
individually and can either be agreed jointly or recommended by your specialist dealer
User-manual-HighLine-v.02
Fig 7.3.1: Section of the exploded view of the upper part
of the ice maker
01/2021
57

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Highline w25 wHighline w55 leHighline w55 w

Table des Matières