WARNING:
NEGATIVE (-) battery terminal first.
5. Remove the battery holder.
To do a check of the battery
Do a check of the battery daily.
a) Turn the ignition key to the "I" position.
b) Examine the battery gauge in the display. It must
not be below 12V.
94°F
13.8
If the battery gauge is below 12V, charge or replace
the battery.
Replace the battery if it cannot keep the voltage.
This can occur if the product is not operated for a
long time. For information about recommended
Technical data on page 48 .
batteries, refer to
Charge the battery regularly.
Keep the battery terminals and the battery cables
clean.
To do an emergency start of the engine
If the battery is too weak to start the engine, you can use
jumper cables to do an emergency start. This product
has a 12 V system with negative ground. The product
that is used for the emergency start must also have a 12
V system with negative ground and minimum 700 CCA.
To connect the jumper cables
WARNING:
of explosive gas that comes from the
battery. Do not connect the negative
terminal of the charged battery to or near the
negative terminal of the weak battery.
CAUTION:
your product to start other vehicles.
42
Always disconnect the
1000
25°F
89.0
123
Risk of explosion because
Do not use the battery of
1. Connect one end of the red battery cable to the
POSITIVE (+) battery terminal (A) on the weak
battery.
B
A
2. Connect the other end of the red battery cable to the
POSITIVE (+) battery terminal (B) on the charged
battery.
WARNING:
the red battery cable touch the chassis.
This will cause a short circuit.
3. Connect one end of the black battery cable to the
NEGATIVE (-) battery terminal (C) on the charged
battery.
4. Connect the other end of the black battery cable to a
CHASSIS GROUND (D), away from the fuel tank
and the battery.
5. Start the product and then remove the jumper
To remove the jumper cables on
cables. Refer to
page 42 .
To remove the jumper cables
Note:
Remove the jumper cables in the opposite
sequence to how you connect them.
1. Remove the BLACK cable from the chassis.
2. Remove the BLACK cable from the fully charged
battery.
3. Remove the RED cable from the 2 batteries.