Technical Data; Tank; Pump; Delivery Nozzle - Cemo Cas-System Mode D'emploi

Table des Matières
Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 26

2. Technical data

2.1

Tank

Trolley:
Length [cm]:
Width [cm]:
Height [cm]:
Weight when empty [kg]:
Nominal volume [l]:
Total weight when full [kg]:
- Diesel
- AdBlue
®
Environmental conditions:
Operating temperature range:
2.2

Pump

Voltage (tolerance):
Fuse:
Power:
Delivery rate:
max. delivery pressure:
Liquid temperature:
2.3
Delivery nozzle
Delivery nozzle Ø [mm] Connection
Diesel:
23
AdBlue:
19
-10 °C to +40 °C (diesel)
-5 °C to +40 °C (AdBlue
Pump 12 V CENTRI SP30:
12 VDC (± 10%)
25 A
220 W
approx. 30 l/min
approx. 1.1 bar
with hose nozzle DN 19 with swivel joint
with hose nozzle DN 20
60 l
90
53
38
13.5
60
64.5
78.5
)
®
Pump 18 V CENTRI SP30:
18 VDC
electronic
220 W
approx. 25 l/min
approx. 1.1 bar
-10 °C to +40 °C (Diesel)
-5 °C to +40 °C (AdBlue
100 l
100
59
43
19.5
100
103.5
126.5
)
®
GB
17
Table des Matières
loading