14. Troubleshooting
Fault
The compressor does not
start.
Compressor runs, but no
pressure.
Compressor running,
pressure shown on the
manometer, but tools are
not running.
30 | GB
Possible cause
Mains voltage not present.
Mains voltage too low.
Outdoor temperature too low.
Motor is overheated.
Non-return valve leaking
The seals are damaged.
The drain screw for condensate (7)
leaks.
Hose connections leaking.
Quick-coupler leaking.
Pressure set too low at pressure
regulator (11).
www.scheppach.com
Remedy
Check cable, mains plug, fuse and
socket.
Avoid extension cables that are too long.
Use extension cables with sufficient
conductor cross-section.
Do not operate at outside temperatures
below +5°C.
Let the motor cool down, if necessary,
eliminate the cause of overheating.
Replace the non-return valve.
Replace the seals, have defective seals
replaced at a specialist workshop.
Tighten the screw by hand. Check
the seal on the screw and replace if
necessary.
Check compressed air hose and tools,
replace if necessary.
Check quick coupling, replace if
necessary.
Turn up the pressure regulator further.