7 How to adjust the limit switche
1. Scroll down the parameters untill you visualize P001;
2. confirm by pressing the [OK] key;
3. by pressing [+] (OPEN) and [-] (CLOSE), move the leaf
in the opening position and adjust the limit switch
cam so that it pushes the microswitch in that point;
Repeat adjusting the closing limit switch.
4. Confirm by pressing the [OK] key (display shows
again P001).
WARNING If the Operator 2 is present, repeat the previous settings using P002.
8 Motor stroke learning
1. Scroll down the parameters with [+] and [-] keys until you visualise P003;
2. Access the parameter by pressing the [OK] key;
3. When "APPr" flashes, continue pressing the [OK] key;
4. Release the [OK] key when "APPr" stops flashing; Start the learning procedure with operator 1 opening (if it starts closing, disconnect
the power supply, inverse the operator cables and repeat the operation);
5. Wait for the door (or doors in case of using 2 motors) searches and stops on the opening stop and then on the closing stop.
If you want to anticipate the stopping strokes in opening, you can manually intervene by giving an impulse to "Start" button (or
pressing the "OK" on the control panel) simulating the stroke.
6. Once the procedure is ended, the display will show "- - - -".
WARNING (only Type 01 and Type 03) Once you have executed the learning stroke, operate a complete cycle (opening/closing) and then
check the manual release to make sure it is working properly. If it's to "hard" increase the value of P057 of 1 or more.
9 Transmitters learning
9.1 Transmitters coding selection
1. Scroll down the parameters with [+] and [-] keys until you visualise
P027;
2. Confirm by pressing on the [OK] key;
3. Select the type of transmitter by scrolling [+] and [-] keys:
- d000=fix rolling-code (suggested);
- d001=complete rolling-code;
- d002=dip-switch;
- d003=DART;
4. Confirm by pressing on the [OK] key (display shows again P027).
Warning: If you need to vary the type of encoding, and only if other remotes
with different encoding are memorized, you need to erase memory (P004)
AFTER you have set the new encoding.
NET24N
31