3 Selection type of operators
1. Scroll down the parameters with [+] and [-] keys until you visuali-
se P028;
2. Access the parameter by pressing the [OK] key;
3. Acting on [+] and [-] keys, set:
Type 00
• 005 6/24N
• 000 GEKO
(BOOST) - 6/24X
• 001 LOOK - MAC
(BOOST)
- STING
• 006 9/24N -
• 002 GHOST 100 -
9/24X
GHOST 200
• 007 REV24
• 003 502/24 -
• 008 REV24/M
ANGOLO
BOOST
• 004 502MT/24
• 005 GEKO/X
Warning: If you are using non DEA System operators, set the parame-
ter on the closer value for family type and performances.
4. Confirm your choice by pressing the [OK] key (display returns
again to P028).
4 Selection operating with or without encoder
Warning: Remember to correctly set the jumpers J5 and J9.
1. Scroll down the parameters with [+] and [-] keys until you visuali-
se P029;
2. Access the parameter by pressing the [OK] key;
3. Acting on [+] and [-] keys, set:
- d000=for operators with encoder;
- d001=for operators without encoder;
4. Confirm your choice by pressing the [OK] key (display returns
again to P029).
5 Selection 1 or 2 operators functioning
1. Scroll down the parameters with [+] and [-] keys until you visuali-
se P030;
2. Access the parameter by pressing the [OK] key;
3. Acting on [+] and [-] keys, set:
- d001=for a single motor operating;
- d002=for 2 motors operating;
4. Confirm your choice by pressing the [OK] key (display returns
again to P030).
6 Selection of direction of motion (only Type 00 and Type 03)
1. Scroll down the parameters with [+] and [-] keys until
you visualise P063;
2. Access the parameter by pressing the [OK] key;
3. Acting on [+] and [-] keys, set:
- d000=motor in standard position;
- d001=motor in inverted position;
4. Confirm your choice by pressing the [OK] key (display
returns again to P063).
Warning: The parameter automatically reverses the
motors output open/close.
Warning: Changing this parameter you need to change
the parameters for the opening and closing limit switches.