NET24N
Index
1
Product Description
2
Technical data
3
4
Configurations
5
6
SYMBOLS
The following symbols are used within this manual to indicate potential hazards.
Important safety notice. Failure to follow these instructions may result in serious injury or damage to property. Failure to do so
may result in product malfunction and create a hazardous situation.
Important safety notice. Contact with live parts can result in death or serious injury.
Important information for installing, programming or commissioning the product.
1 PRODUCT DESCRIPTION
NET24N is a universal control panel for DEA System 1 or 2 24V
The main feature of this control board is its ease of configuration of inputs and outputs according to any needs thus ensuring adaptability
to any type of automation. It is therefore easy to set up and exclude all unnecessary functions.
2 TECHNICAL DATA
Power supply (V)
Rated power transformer (VA)
Fuse F1 (A) (transformer)
Fuse F2 (A) (batteries input)
Outputs 24V
motors
maximum output current (A)
Auxiliaries power supply output
Stabilized power supply output for safety devices
"Warning" output
Electric lock output
Flashing light output
Operating temperature range (°C)
Receiver frequency
Transmitters type of coding
Max remote controllers managed
Universal control panel for 24V operators
Operating instructions and warnings
7
25
8
25
9
26
10
28
11
Product Disposal
29
33
operators automations with or without encoder.
230 - 240 V ~ (50/60 Hz)
2 x 7A (oppure 1 x 10A)
Warning: In absolute terms, the maximum current for each output should not
exceed 10A when using a single motor and 7A when using 2 motors.
24V
24V
max 1 art. 110 or 24V
HCS fix-code - HCS rolling code - Dip-switch - DART
See wiring diagram
Fuse T 15A L 250V
(24V_AUX + 24V_ST
= max 200mA)
24V
max 15W
max 5W configurable output
24V
max 15W
-20÷50 °C
433,92 MHz
100
NET24N
36
37
38
44
44
25