Operating Elements And Connections - Monacor DMT-4010RMS Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20
Contents
GB
1

Operating Elements and Connections 12

2
Safety Notes . . . . . . . . . . . . . . . . . . . . 13
3
Applications . . . . . . . . . . . . . . . . . . . . 13
4
Attaching the Label . . . . . . . . . . . . . . . 13
5
Operation . . . . . . . . . . . . . . . . . . . . . . 13
5.1
Connecting the test leads . . . . . . . . 14
6
Measuring . . . . . . . . . . . . . . . . . . . . . . 14
6.1
Measuring voltages . . . . . . . . . . . . . 14
6.2
Measuring currents . . . . . . . . . . . . . 14
6.3
Measuring resistances . . . . . . . . . . 15
6.4
Testing the continuity . . . . . . . . . . . . 15
6.5
Testing diodes . . . . . . . . . . . . . . . . . 15
6.6
Measuring capacitances . . . . . . . . . 15
6.7
Measuring frequencies . . . . . . . . . . 16
6.8
Measuring temperatures . . . . . . . . . 16
7
Additional Functions . . . . . . . . . . . . . . 16
7.1
Manual range selection . . . . . . . . . . 16
7.2
Data hold function . . . . . . . . . . . . . . 16
7.3
minimum value . . . . . . . . . . . . . . . . 16
7.4
Indicating short peaks . . . . . . . . . . . 17
8
or Replacing Fuses . . . . . . . . . . . . . . . 17
8.1
Inserting a battery . . . . . . . . . . . . . . 17
8.2
Replacing fuses . . . . . . . . . . . . . . . . 17
9
Specifications . . . . . . . . . . . . . . . . . . . 18
12
All operating elements and connections
described can be found on the fold-out
page 3.
1 Operating Elements
and Connections
1 Button "RANGE" for manual range selec-
tion
2 Button "HOLD" to hold a measured value
3 Button "MODE" to switch the measuring
mode (e. g. DC or AC voltage measure-
ment, temperature measurement in Cel-
sius or Fahrenheit)
4 Jack "10A" for the red test lead for measur-
ing currents up to 10 A max.
5 Jack "µA/mA" for the red test lead for
measuring currents up to 400 mA max.
6 LC display with 3
and bar graph
7 Button "PEAK" to indicate short peak val-
ues when measuring voltages and currents
8 Button "MAX / MIN" to indicate the maxi-
mum value and minimum value during a
measurement
9 Button
for the display illumination
10 Selector switch for the measuring functions
11 Jack "V Hz Ω CAP °C °F" for the red test
lead when measuring voltages, frequen-
cies, resistances and capacitances; when
measuring temperatures, connect the pos-
itive pole of the type K temperature sensor
to this jack
12 Jack "COM" for the black test lead or, when
measuring temperatures, for the negative
pole of the type K temperature sensor
13 Sleeves to seal the two red jacks not used
to ensure protection of the meter according
to IP 67 (e. g. to protect it against humidity
for outdoor applications)
3
/
-digit digital indication
4

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

29.2020

Table des Matières