Antenna Installation - BFT ALPHA Instructions D'utilisation Et D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
DIP3)
BLI - Blocks impulses.
ON:
START commands are not accepted during the opening phase.
OFF: START commands are accepted during the opening phase.
DIP4)
3P/4P - 3 Steps/4 Steps
ON:
Enables 3-step logic.
OFF: Enables 4-step logic.
DIP5)
CODE FIX – Fixed code.
ON:
Activates incorporated receiver in fixed code mode.
OFF: Activates incorporated receiver in rolling-code mode.
DIP6)
RADIO LEARN - Radio transmitter programming
ON:
This enables transmitter storage via radio:
1 – First press the hidden key (P1) and then the normal key (T1, T2,
T3 or T4) of a transmitter already memorised in standard mode by
means of the radio menu.
2 – Within 10s press the hidden key (P1) and the normal key (T1, T2,
T3 or T4) of a transmitter to be memorised.
The receiver exits the programming mode after 10s, other new tran-
smitters can be entered before the end of this time.
This mode does not require access to the control panel.
OFF: This disables transmitter storage via radio. The transmitters can only
be memorised using the appropriate Radio menu.
DIP7)
SCA – Gate-open warning light or 2nd radio channel.
OFF: Activates relay output in Gate-open warning light mode.
ON:
Activates relay output as 2nd radio channel.
DIP8)
FAST CLOSE
ON:
Closes the gate after photocell disengagement, before waiting for the
end of the TCA set.
OFF: Command not entered.
7) TRIMMER ADJUSTMENT (Fig.3)
TCA (Dip1 ON).
It is used to set the automatic closing time, after which the gate closes
automatically (adjustable from 0 to 90 s.).
TW
It is used to set the motor working time, after which the motor stop (ALPHA:
adjustable from 0 to 90 s. / ALPHA BOM: 10 s). When using electrical limit
switches, increase the motor stopping time by a few seconds with respect to
the leaf closing time.
8) INTEGRATED RECEIVER TECHNICAL SPECIFICATION
Receiver output channels:
-
output channel 1, if activated, controls a START command.
-
output channel 2, if activated, controls the excitation of the 2nd radio
channel relay for 1s.
Transmitter versions which can be used:
all Rolling Code transmitters compatible with

ANTENNA INSTALLATION

Use an antenna tuned to 433MHz.
For Antenna-Receiver connection, use RG8 coaxial cable.
The presence of metallic masses next to the antenna can interfere with radio
reception. In case of insufficient transmitter range, move the antenna to a
more suitable position.
9) PROGRAMMING
Transmitter storage can be carried out in manual mode, or by means of
the UNIRADIO programmer which allows you to create installations in the
"collective receivers" mode, as well as manage the complete installation
database using the EEdbase software.
10) MANUAL PROGRAMMING
In the case of standard installations where no advanced functions are required,
it is possible to proceed to manual storage of the transmitters
1) If you wish the transmitterT key to be memorised as Start, press thSW1 button
on the control unit, otherwise if you wish the transmitter key to be memorise
as second radio channel, press the SW2 button on the control unit.
2) When the DL1 LED blinks, press the transmitter P1 hidden key, and the
DL1 LED will stay on permanently.
3) Press the key to be memorised on the transmitter, LED DL1 will start
blinking again.
4) To memorise another transmitter, repeat steps 2) and 3).
5) To exit the storage mode, wait until the LED is switched off completely.
IMPORTANT NOTE: ATTACHTHE ADHESIVE KEY LABELTOTHE FIRST
MEMORISED TRANSMITTER (MASTER).
INSTALLATION MANUAL
In the case of manual programming, the first transmitter assigns the key
code to the receiver; this code is necessary in order to carry out subsequent
cloning of the radio transmitters.
10.1) CONTROL UNIT MEMORY CANCELLATION
In order to cancel the control unit memory completely, simultaneously press
for 10 seconds the SW1 and SW2 buttons on the control unit (DL1 LED
blinking). Correct memory cancellation will be indicated by the DL1 LED
staying on permanently. To exit the storage mode, wait until the LED is
switched off completely.
11) RECEIVER CONFIGURATION
The on-board receiver combines characteristics of utmost safety in copying
variable code (rolling code) coding with the convenience of carrying out
transmitter "cloning" operations thanks to an exclusive system.
Cloning a transmitter means creating a transmitter which can be automatically
included within the list of the transmitters memorised in the receiver, either
as an addition or as a replacement of a particular transmitter.
Cloning by replacement is used to create a new transmitter which takes the
place of the one previously memorised in the receiver; in this way a specific
transmitter can be removed from the memory and will no longer be usable.
Therefore it will be possible to remotely program a large number of additional
transmitters or, for example, replacement transmitters for those which have
been lost, without making changes directly to the receiver.
When coding safety is not a decisive factor, the on-board receiver allows
you to carry out fixed-code additional cloning which, although abandoning
the variable code, provides a high number of coding combinations, there-
fore keeping it possible to "copy" any transmitter which has already been
programmed .
12) RADIO-TRANSMITTER CLONING (Fig.7)
Rolling-code cloning / Fixed-code cloning
Make reference to the UNIRADIO Instructions and the CLONIX Program-
ming Guide.
12.1) ADVANCED PROGRAMMING: COLLECTIVE RECEIVERS
Make reference to the UNIRADIO Instructions and the CLONIX Program-
ming Guide.
13) ACCESSORIES
SPL (fig.4).
Pre-heating optional board. Recommended for temperatures below -10°C.
(In the case of hydraulic motors).
ME (fig.5).
Optional board used to connect a 12V~ electric lock.
Note: the ME optional board is not operated by the START control of the
integrated radio board. For the correct functioning of the ME optional board
use one of the following configurations:
1. use the second radio channel as START control and perform the necessary
connections to the terminal board.
.
2. use the plug-in radio receiver.
EBP (fig.2).
The EBP electric lock with continuous service can be connected directly to
terminals 1 and 4.
14) SCRAPPING
Warning: This operation should only be carried out by qualified person-
nel. Materials must be disposed of in conformity with the current regulations.
In case of scrapping, the automation devices do not entail any particular risks
or danger. In case of materials to be recycled, these should be sorted out
by type (electrical components, copper, aluminium, plastic etc.).
15) DISMANTLING
Warning:This operation should only be carried out by qualified person-
nel. When the control unit is disassembled to be reassembled on another
site, proceed as follows:
Disconnect the power supply and the entire electrical installation.
In the case where some of the components cannot be removed or are
damaged, they must be replaced.
The descriptions and illustrations contained in the present manual are
not binding. The Company reserves the right to make any alterations
deemed appropriate for the technical, manufacturing and commercial
improvement of the product, while leaving the essential product fea-
tures unchanged, at any time and without undertaking to update the
present publication.
ENGLISH
ALPHA-ALPHA BOM - Ver. 04 -
9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Alpha bom

Table des Matières