General Safety; General Outline; Technical Data - BFT ALPHA Instructions D'utilisation Et D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
ENGLISH
Thank you for buying this product, our company is sure that you will be more
than satisfied with its performance.
This product is supplied with an "Instruction Manual" which should be read
carefully as it provides important information about safety, installation, ope-
ration and maintenance.
This product complies with recognised technical standards and safety regula-
tions. We declare that it is in conformity with the following European Directives:
89/336/EEC, 73/23/EEC and subsequent amendments.

1) GENERAL SAFETY

WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.
The "Warnings" leaflet and "Instruction booklet" supplied with this
product should be read carefully as they provide important information
about safety, installation, use and maintenance.
Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children's reach.
Keep the instructions together with the technical brochure for future
reference.
This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in
this documentation could damage the product and be dangerous.
The Company declines all responsibility for any consequences resulting
from improper use of the product, or use which is different from that
expected and specified in the present documentation.
Do not install the product in explosive atmosphere.
The construction components of this product must comply with the following
European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subse-
quent amendments. As for all non-EEC countries, the above-mentioned
standards as well as the current national standards should be respected
in order to achieve a good safety level.
The Company declines all responsibility for any consequences resulting
from failure to observe GoodTechnical Practice when constructing closing
structures (door, gates etc.), as well as from any deformation which might
occur during use.
The installation must comply with the provisions set out by the following
European Directives:89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent
amendments.
Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if fitted.
Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3,5 mm.
Check that a differential switch with a 0.03A threshold is fitted just before
the power supply mains.
Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an
earth terminal.
Fit all the safety devices (photocells, electric edges etc.) which are needed
to protect the area from any danger caused by squashing, conveying and
shearing.
Position at least one luminous signal indication device (blinker) where it
can be easily seen, and fix a Warning sign to the structure.
The Company declines all responsibility with respect to the automation safety
and correct operation when other manufacturers' components are used.
Only use original parts for any maintenance or repair operation.
Do not modify the automation components, unless explicitly authorised
by the company.
Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.
Do not allow persons or children to remain in the automation operation area.
Keep radio control or other control devices out of children's reach, in
order to avoid unintentional automation activation.
The user must avoid any attempt to carry out work or repair on the automa-
tion system, and always request the assistance of qualified personnel.
Anything which is not expressly provided for in the present instructions,
is not allowed.
Installation must be carried out using the safety devices and controls
prescribed by the EN 12978 Standard.

2) GENERAL OUTLINE

The ALPHA-ALPHA BOM mod. control units have been designed to control
one single operator.

3) TECHNICAL DATA

Power supply: ..............................................................230V±10%, 50Hz(*)
Mains insulation/very low voltage: ...................................> 4M
Working temperature: ............................................................... -10 / +55°C
Dielectric strength:.... ..................mains/low voltage 3750V
8 -
ALPHA-ALPHA BOM - Ver. 04
INSTALLATION MANUAL
Gate-open warning light: .................................................... 24V
Supply to accessories: ..................................24V
Incorporated Rolling-Code radio receiver: .............. Frequency 433.92MHz
Coding: ..............................................Rolling-Code Algorithm to be cloned
No. combinations: ........................................................................ 4 milliard
Antenna impedance:........................................................... 50Ohm (RG58)
Max no. radio transmitters to be memorised:.......................................... 63
Dimensions: ..............................................................................see figure 1
(* other voltages available on request)
4) TERMINAL BOARD CONNECTIONS (Fig.2)
For the electric diagram and the cross section of the cables refer to the
manual of the actuator.
WARNING – During the wiring and installation operations, refer to the current
standards as well as principles of good technical practice.
Wires powered at different voltages must be physically separated, or suitably
insulated with at least 1 mm extra insulation. The wires must be clamped by
an extra fastener near the terminals, for example by bands.
All the connection cables must be kept at an adequate distance from the
dissipator.
Connect the yellow/green conductor of the power supply cable to the earth terminal.
230V cables must be physically separate from the safety very low voltage circuits.
Keep the mains voltage connections definitely separate from the (24V) very
low voltage connections.
The capacitors inside the control unit must be positioned in such a way
as not to decrease the surface and air distances with respect to the safety
very low voltage.
WARNING! For connection to the mains, use a multipolar cable with a
minimum of 3x1.5mm
sly mentioned regulations. For example, if the cable is out side (in the
open), it has to be at least equal to H07RN-F, but if it is on the inside
(or outside but placed in a plastic cable cannel) it has to be or at least
egual to H05VV-F with section 3x1.5mm
JP1
1-2
Power supply 230V +/- 10% 50/60 Hz (Neutral to terminal 1).
3-4-5 Connection to motor M (terminal 4 common, terminals 3-5 motor and
capacitor drive).
1-4
Connection to blinker and electric lock 230V mod. EBP.
JP2
7-8
START pushbutton or key selector (N.O.).
7-9
STOP pushbutton (N.C.). If not used, leave the bridge connected.
7-10
Photocell input or pneumatic edge (N.C.). If not used, leave the bridge
connected.
7-11
Opening limit switch (N.C.). If not used, leave the bridge con-
nected.
7-12
Closing limit switch (N.C.). If not used, leave the bridge connected.
13-14 Output 24V
15-16 Output for gate-open warning light outputor alternatively 2nd radio channel.
17-18 Antenna input for radio-receiver plug-in board
JP3
19-20 Pedestrian input (N.O.)
WARNING: the pedestrian function can be used provided that limit
switches are fitted.
JP4 Radio-receiver board connector, 1-2 channels.
Fig.7 shows a general wiring diagram.
5) LED (Fig.3)
The ALPHA-ALPHA BOM control units are provided with a series of self-
diagnosis LEDs which control all the functions.
DL1: Incorporated radio receiver LED
DL2: START - Start - goes on when a start command is given.
DL3: STOP - Stop - goes off when a start command is given.
DL4: PHOT - Photocell - goes off when the photocells are not aligned or in
the presence of obstacles.
DL5: SWO - Goes off when the opening limit switch is operated.
DL6: SWC - Goes off when the closing limit switch is operated.
6) DIP-SWITCH SELECTION (Fig.3)
DIP1)
TCA [ON] - Automatic closing time TCA.
ON:
Activates automatic closing
OFF: Excludes automatic closing
DIP2)
FCH [ON] - Photocells.
ON:
Photocells are only active in the closing phase.
Ω
, 500V
OFF: Photocells are active both in the closing and opening phase.
~
per 1 minute
cross section and complying with the previou-
2
.
2
~
supply to photocells or other devices.
~
, 3W max
~
, (0.2A max absorption)
(17 signal-18
braid).

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Alpha bom

Table des Matières