General Safety; General Outline; Technical Specifications - BFT LEO D MA Instructions D'utilisation Et D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20
Thank you for buying this product, our company is sure that you will be more
than satisfied with the product's performance. The product is supplied with
a "Warnings" leaflet and an "Instruction booklet". These should both be
read carefully as they provide important information about safety, installation,
operation and maintenance. This product complies with the recognised
technical standards and safety regulations. We declare that this product is
in conformity with the following European Directives: 89/336/EEC and 73/
23/EEC, 98/37/EEC (and subsequent amendments).

1) GENERAL SAFETY

WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.
The "Warnings" leaflet and "Instruction booklet" supplied with this product
should be read carefully as they provide important information about
safety, installation, use and maintenance.
Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children's reach.
Keep the instructions together with the technical brochure for future
reference.
This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in this
documentation could damage the product and be dangerous.
The Company declines all responsibility for any consequences resulting
from improper use of the product, or use which is different from that
expected and specified in the present documentation.
Do not install the product in explosive atmosphere.
The construction components of this product must comply with the following
European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent
amendments. As for all non-EEC countries, the above-mentioned standards
as well as the current national standards should be respected in order to
achieve a good safety level.
The Company declines all responsibility for any consequences resulting
from failure to observe Good Technical Practice when constructing closing
structures (door, gates etc.), as well as from any deformation which might
occur during use.
The installation must comply with the provisions set out by the following
European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent
amendments.
Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if fitted.
Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3,5 mm.
Check that a differential switch with a 0.03A threshold is fitted just before
the power supply mains.
Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an
earth terminal.
Fit all the safety devices (photocells, electric edges etc.) which are needed
to protect the area from any danger caused by squashing, conveying and
shearing.
Position at least one luminous signal indication device (blinker) where it
can be easily seen, and fix a Warning sign to the structure.
The Company declines all responsibility with respect to the automation
safety and correct operation when other manufacturers' components are
used.
Only use original parts for any maintenance or repair operation.
Do not modify the automation components, unless explicitly authorised by
the company.
Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.
Do not allow persons or children to remain in the automation operation
area.
Keep radio control or other control devices out of children's reach, in order
to avoid unintentional automation activation.
The user must avoid any attempt to carry out work or repair on the
automation system, and always request the assistance of qualified
personnel.
Anything which is not expressly provided for in the present instructions, is
not allowed.
Installation must be carried out using the safety devices and controls
prescribed by the EN 12978 Standard.

2) GENERAL OUTLINE

The LEO-D-MA control panel is supplied by the manufacturer with standard
setting. Any alteration must be set by means of the incorporated display
programmer or by means of UNIPRO. The Control unit completely supports
the EELINK protocol.
It is available in two versions: one for external installation, inside the SD
INSTALLATION MANUAL
box, the other fitted and pre-wired inside the controller.
Its main characteristics are:
-
Slow down of end-of-run speed.
-
Electronic torque setting
-
Adjustable electrodynamic braking
-
Closing / opening limit-switch inputs
-
Separate inputs for safety devices
-
Clock input
-
Serial protocol connection input (optional)
-
Incorporated radio receiver
The board is provided with a terminal board which can be pulled out for
easier maintenance or replacement. The board is supplied with a series of
pre-wired jumpers to facilitate the installer's work.
The jumpers relate to the following terminals: 21-23, 21-24 and 21-30. If the
above-mentioned terminals are in use, remove their respective jumpers.
CHECK
The control unit runs a check on the operating relays and safety mechanisms
(photocells, sensor ridge, etc.) before performing opening and closing
cycles.
CONNECTION OF PHOTOCELLS AND SENSOR RIDGE:
By convention, refer to a receiver (Rx- fig.7) with 5 terminals of which
terminals 1 and 2 are for the 24V AC power supply, terminal 3 is shared,
terminal 4 is the normally closed contact when at rest, terminal 5 is the
normally open contact when at rest. The contact is not powered.
LEGEND
RX: photocell or infrared edge receiver.
TX: photocell or infrared edge transmitter.
Numerous combinations can be obtained between photocells and infrared
edges; the most frequently used types of connections are illustrated in
figures 7 to 14.
-
Fig.7 shows the connection of LEO-D-MA with 1 photocell and 1 infrared
edge unchecked. In the logic menu, set the "test phot" and "test bar"
functions to OFF.
-
Fig.8 shows the connection of LEO-D-MA with 1 photocell and 1 infrared
edge checked.
8a
8b
8a+8b
In the logic menu, set the "test phot" and "test bar" functions to ON.
-
Fig.9 shows the connection of LEO-D-MA with 2 photocells and 2 infrared
edges checked.
9a
9b
9a+9b
In the logic menu, set the "test phot" and "test bar" functions to ON.
-
Fig.10 shows the connection of LEO-D-MA with 3 photocells and 3 infrared
edges checked.
10a
10b
10a+10b : 3 photocells + 3 edges checked
In the logic menu, set the "test phot" and "test bar" functions to ON.
-
Fig.11 shows the connection of LEO-D-MA with 4 photocells and 1 infrared
edge checked.
11a
11a+11b : 4 photocells + 1 edge checked
In the logic menu, set the "test phot" and "test bar" functions to ON.
-
Fig.12 shows the connection of LEO-D-MA with 1 photocell and 4 infrared
edges checked.
11b
11a+11b : 1 photocell + 4 edges checked
In the logic menu, set the "test phot" and "test bar" functions to ON.
-
Fig.13 shows the connection of LEO-D-MA with 4 photocells and 2 infrared
edges checked.
In the logic menu, set the "test phot" and "test bar" functions to ON.
-
Fig.14 shows the connection of LEO-D-MA with 2 photocells and 4 infrared
edges checked.
In the logic menu, set the "test phot" and "test bar" functions to ON.

3) TECHNICAL SPECIFICATIONS

Power supply: ................................................................ 230V±10% 50Hz*
Mains/low voltage insulation: ....................................... > 2MOhm 500Vdc
Dielectric strength: ..................... mains/low voltage 3750Vac for 1 minute
Motor output current: .................................................................... 1.5Amax
Maximum motor power: ................................................................... 750W
Supply to accessories: ................................... 24Vac (1A max absorption)
: 1 photocell checked
: 1 infrared edge checked
: 1 photocell + 1 edge checked
: 2 photocells checked
: 2 infrared edges checked
: 2 photocells + 2 edges checked
: 3 photocells checked
: 3 infrared edges checked
: 4 photocells checked
: 4 infrared edges checked
ENGLISH
13
LEO-D-MA - Ver. 01 -