Troubleshooting; Transport; Scheduled Maintenance Table - Nilfisk Advance BA 450 Manuel D'emploi Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

USE AND MAINTENANCE MANUAL

TROUBLESHOOTING

(See Fig. K)
Motors do not work
1.
Check the battery cables for poor connections
2.
Check that the battery charger is connected to the
batteries (optional)
3.
Charge the batteries
4.
Check the battery charger
5.
Check that the autoresetting fuses are not
de-energized
Poor water vacuum
1.
Recovery tank full, float shut-off closed
2.
Vacuum system locked (squeegee hose or float cage
clogged)
3.
Disconnected or damaged vacuum hoses
4.
Worn or damaged squeegee lips
5.
Tank cover not seated properly
6.
Dirty turbine pre-filter

SCHEDULED MAINTENANCE TABLE

Operation
Clean the squeegee
Clean the float grille
Clean the solution tank
Clean the solution filter
Clean the vacuum pre-filter
Clean the squeegee
Inspect the tanks and hoses
Charge the batteries after use
Check the battery fluid level
Check the brush/pad and pad-holder
Check the vacuum motor operation
8
Squeegee-provoked lining
1.
Debris under the squeegee lip
2.
Worn, nicked or torn squeegee lip
3.
Debris on the squeegee lip

TRANSPORT

Transport the machine on a vehicle and fix it with
adequate clamping systems.
Daily
Weekly
Every six months
08812382(5)2004-05 A