WARNING:
To avoid serious personal injury, always check for gas
leaks any time the propane cylinder is disconnected and
then reconnected.
After installing a 20 lb. propane cylinder, check for leaks
at both the generator and cylinder connection before use.
 Make sure the propane hose adaptor is properly con-
nected to the generator and the propane cylinder.
 Turn handwheel counterclockwise to open the cylinder
valve.
NOTE: If you hear a rushing sound, immediately turn off
the cylinder valve. This sound means there is a major leak
at the connection. Correct the problem before proceeding.
 Using a clean paint brush and a 50/50 mixture of mild
soap and water, brush soapy solution over the connection
at the propane cylinder.
 "Growing" bubbles indicate a leak. Close the cylinder
valve and retighten connection.
NOTE: If leaks cannot be stopped, do not try to repair.
Replace the propane cylinder.
 If you are not using the generator immediately after the
leak test, close the cylinder valve by turning the valve
clockwise.
SAFETY TIPS WHEN USING A PROPANE
CYLINDER TO FUEL GENERATOR
 Before opening the propane cylinder valve, check the
coupling nut for tightness and perform a leak test as
described earlier in this manual.
 When generator is not in use, remove the 1 lb. cylinder
or close the 20 lb. cylinder valve.
 If the regulator frosts, immediately turn off the generator,
wait 5 minutes for unit to cool, and then remove the 1 lb.
cylinder or close the 20 lb. cylinder valve. This indicates
a problem with the propane cylinder and it should not be
used. Return the cylinder to the supplier.
STARTING THE ENGINE
See Figures 10 - 11.
NOTICE:
On a level surface with the engine off, check the lubricant
level before each use of the generator.
NOTE: If location of generator is not level, the unit may not
start or may shut down during operation.
OPERATION
  Unplug all loads from the generator.
  Make sure the propane cylinder is tested and installed as
described earlier in this manual. If using a 20 lb. cylinder,
open the cylinder valve completely.
  Press the primer button one time for approximately two
seconds.
 Pull the recoil starter grip until the engine runs.
NOTE: Do not allow the grip to snap back after starting;
return it gently to its original place.
STOPPING THE ENGINE
See Figure 12.
To stop the engine under normal operating conditions:
  Remove any load from the generator.
  Press and hold the engine switch until the engine stops.
  Remove the 1 lb. cylinder or close the 20 lb. cylinder valve
completely.
To stop the unit quickly in an emergency:
  Press and hold the engine switch until the engine stops.
  Remove the 1 lb. cylinder or close the 20 lb. cylinder valve
completely.
WARNING:
While operating and storing, keep at least 3 feet of clear-
ance on all sides of this product, including overhead.
Allow a minimum of 30 minutes of "cool down" time
before storage. Heat created by muffler and exhaust
gases could be hot enough to cause serious burns and/
or ignite combustible objects.
MOVING THE GENERATOR
See Figure 13.
  Turn off the generator.
 Allow 30 minutes of "cool down" time before storing the
machine. Make sure engine and exhaust of unit are cool.
 Carry by the carry handle.
 Grasp the handle firmly with one hand.
 Lift the generator and carry the unit at your side to the
desired location.
 Lower the generator until it sits securely on a flat surface.