RCM Metro Série Manuel D'utilisation Et D'entretien page 65

Table des Matières

Publicité

The scrubber is equipped with two high frequency electronic control units with energy recovery,. The unit 4Qbig (1 - fi g.15) controls the drI ve and the unit DCM06 (2 - fi g.15) controls
the squeege and brushes . This type of device also has diagnostics for any problems which might occur. The number of times the LED on the control unit fl ashes identifi es the type of
operating error which has occurred.
No. of Flashes / Error encountered (CONTROL UNIT "4Qbig" - FIG.15 - Pos.1)
Led OFF / The controller is off on with no errors
Led steadily ON / The controller is communicating wiht the terminal or the computer while the operator is chanching parameters
Led rapidly fl ashing - NOT SERIOUS ERRORS
Flashes
Code
Error
-
1C
Potentiometer not at 0
Forward and reverse controls
-
26
enable at the same time.
Led slowly fl ashing / SERIOUS ERRORS
Flashes
Code
Error
1
1F
Moving motor on start
2
08
Realy contact fault
3
1D
Too low supply voltage
4
1E
Too high supply voltage
5
10
Relay driver fault
6
1B
Broken pot.
7
18
Temperature fault
8
23
Fault on turn off
9
27
Fault on parameter'setting
10
2D
Fault on Checksum
12
22
Fault on acquisition
16
2B
Too high rotor current (1)
19
28
Program memory CRC fault
20
29
Parameters memory CRC fault
21
2F
Device not registered
22
2E
External fault
ELECTRONIC CONTROL UNITS
(FIG.15)
Possible causes and solutions
Potentiometer is not in neutral position
Put running switches in off position and the potentiometer in neutral position.
Possible causes and solutions
When the key switch has been switched on the motor was turning. If the error persists power parts could be damaged. Contact Service center.
Contact Service center.
Battery voltage is decreased below the min. voltage.
Battery voltage has increased above the max value or has exceeded the max voltage allowed for the controller
Contact Service center.
Contact Service center.
Check controller and base coupling. If the error persists , Contact Service center.
The controller has been switched off when the vehicle was moving. Always turn the controller off when the vehicle is stopped
Some parameters are not correct. Contact Service center.
Programming procedure has been interrupted. Repeat it
Auto-calibration has not been correctly carried out. Contact Service center.
Contact Service center.
Contact Service center.
Contact Service center.
Contact Service center.
Controller shutoff has been required by the input or serially by another device.
METRO
65

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Metro 1102n33.me.003Metro 1102rn33.me.004Metro 1303n33.me.005

Table des Matières