Burner Cleaning; Turning Off The Stove; Stove Turned Off; Re-Ignition Of The Stove - Bio Bronpi Air Série Instructions D'installation, D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 45
Remember that if it is activated "stand-by mode", when the ambient temperature reaches the value set by the user plus a differential (2ºC) the
stove will be automatically turned off and will be on hold until the ambient temperature falls to the set temperature minus a differential (2ºC).
After that, the stove restarts automatically.
10.5.5

BURNER CLEANING

While the stove is working normally, some automatic cleanings of
the burner take place in 30 minutes intervals. This process consists
of cleaning the rest of pellet remaining in the burner in order to
guarantee a proper working of the stove (see drawing D70) and it
takes 30 seconds.
10.5.6

TURNING OFF THE STOVE

In order to turn off the stove, press button no.4 during a few seconds.
Once it has been turned off, it will start the final cleaning stage, in
which the pellet supply stops and the smoke extractor will be working
to the maximum speed. This stage would not finish until the stove has
reached the appropriate cooling temperature (see drawing D71).
10.5.7

STOVE TURNED OFF

When the stove is turned off, the display shows the following
information (see drawing D72):
10.5.8

RE-IGNITION OF THE STOVE

When the stove is turned off it would not be possible to restart it
up until some safety time goes by and the stove is cold enough. If
you try to start-up the stove, the display will show up the following
information (see drawing D73):
10.5.9

DISPLAY BLOCK

The display of your stove can be locked to prevent accidental
pressing of any of the keys. To do so, it is necessary to make a short
press on the button number 3 and then on button 4 (it is not pressing
both buttons simultaneously). Thus, it will be displayed the following
message (see drawing D74):
To unlock it, proceed likewise; make a short press on the button
number 3 and then on button 4 (it is not pressing both buttons
simultaneously). Thus, it will be displayed the following message
(see drawing D75):

11 ALARMS

In case of an anomaly during the operation, the electronics of the
stove intervene and highlight the irregularities that have ocurred in
the different working phases, depending on the type of fault.
Every alarm situation blocks the stove. By pressing button 4 we can
unblock it. Once the stove has reached the appropriate cooling
temperature, the user can restart it up.
11.1

POWER SUPPLY FAILURE (BLACK OUT)

In the event that power supply is cut for less than 30 seconds, the
stove will restart and continue with its normal working state.
In the event that power supply is cut for greater than 30 seconds,
when power is restored, the stove, as a safety measure, goes
straight to the Final Cleaning stage until the stove temperature
reaches the appropriate cooling temperature.Once the final cleaning
has finished, the stove will turn off until the user ignite it again (see
drawing D76).
11.2

SMOKE TEMPERATURE PROBE ALARM

This alarm goes off when the probe in charge of detecting the
exhaust stack temperature is disconnected or it breaks. During the
alarm status, the stove will be in the turn-off stage (see drawing
D77).
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
16:40
22 ºC
BURNER
CLEANING
21:10
23 ºC
FINAL
CLEANING
21:10
22 ºC
OFF
STAND-BY
COOLING
KEYS
FROZEN
KEYS
FREE
12:42
22 ºC
FINAL
CLEANING
ALARM 2
SMOKE
SENSOR
40
P-2
D70
P-3
D71
P-1
D72
D73
D74
D75
P-3
D76
D77
AIR SERIES

Publicité