5.4

OUTSIDE AIR INTAKE

For the proper operation of the stove, it is essential that there is enough air for the combustion and re/oxygenation of the environment where
it is installed. This means that the air must be able to move for the combustion through some openings connected to the exterior, even when
doors and windows are closed.
It must be placed in so that it cannot be obstructed. It must be connected to the environment where the equipment is installed and it must be
protected by a grate. The minimum area of the outlet should not be less than 100 cm2.
When the air flow comes through openings that are connected to the exterior of adjacent environments, it is important to avoid air intakes in
connection with garages, kitchens, toilets, etc.
The stove is provided with a necessary air intake for the combustion on the back side (40 or 50 mm diameter). It is important this intake is not
blocked and to respect the recommended distances to the wall or near items.
It is recommended the primary air intake connection of the stove with the outside although it is not obligatory. The connection tube material
can be made in any material (PVC, aluminium, polyethylene, etc.), not necessarily metallic. Consider that inside this duct is going to pass air
at the outside temperature.
The models Rita and Zoe are certified as hermetic stoves by the standard EN613 (50 Pa). Therefore, they are models that
are certified to be operated with the PGI system by Poujoulat. Thanks to the hermetic configuration of the air supply line
and smoke tubes of the stove, it can be used in airtight spaces (Passive house - BBC).
Thanks to a sealed combustion chamber, this product can work by collecting oxygen from the outside, which reduces fuel
consumption and increases thermal comfort in the most modern houses (class A).
5.5

HOW TO ASSEMBLE

Most of the models have the smoke exit just on the rear of the stove.
On the other hand, the models Dama, Coral and Abril have the option to connect the smoke exit to the stove, on the side (side exit), by
hitting the side lid which is partially perforated
and connect the pipes to the extractor
using an elbow of 90º of 80 mm diameter, to
consequently connect the rest of the installation
of smoke (registration T, converter, straight
sections, etc).
Models Abril and Carmen, additionally, have
an upper exit in the cast-iron top of the stove. It
will be enough to remove the existing cover of
the top and connect the pipes to the smoke exit
provided in the stove.
In every single case, do not forget to follow the
safety distances of the stove and the pipe with
the walls (see section "safety distance").
6

START UP

The ignition of this kind of equipments is automatic, so, please do not put on the burner any kind of material to ignition.
Before the ignition, follow the next verifications:
It is forbidden to use liquid substances such as alcohol, gasoline, petroleum or similar products. The use of this substance
leads the loss of warranty.
-
The electrical cable must be connected to the electrical network (230 Vac) with a socket equipped with earthing system.
-
The bipolar switch, placed on the rear side of the stove, must be in position I.
-
The pellet tank must be supplied.
-
The combustion chamber must be clean.
-
The burner must be clean and properly placed.
-
The combustion chamber door must be closed correctly.
During the first ignition could happen that the stove has finished the ignition cycle and there is no flame. In this case the stove automatically
starts an alarm state. This happens because the fuel feeder is empty and needs a moment to fill in. To solve this problem start again the stove
(taking into account the previous considerations ) until the flame appears.
The stove, at the beginning, must be subject to different start-up cycles so that all materials and the paint can complete different elastic
expansions.
At the beginning, it is possible that you note smoke or smell which are typically produced when metals are subject to high temperatures or
when the paint is still fresh. This paint is boiled at 80º C for a few minutes when construction, but it must exceed for a time the temperature of
200 ºC before the adhesion to the metallic surfaces.
Therefore, it is important to adopt these measures during the ignition phase:
1.
Assure that there is a good air refill in the place where the equipment is installed.
2.
During the firsts ignitions, keep a low power work and the oven lit during at least 6-10 hours continuously.
3.
Repeat this operation at least 4-5 times or more, depending on the needs.
4.
During the first ignitions, you should not place any object on the equipment and, in particular, on lacquered surfaces. Lacquered
surfaces should not be touched while the equipment is heated.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
28
D11
AIR SERIES

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Air série

Table des Matières