Requirement: tool with operating pressure of
6 bar!
6.5
Special features of the CTL 36 E AC-
LHS
To use the mobile dust extractor in combination
with the PLANEX:
► Use kink-resistant suction hose D 36 mm x
3.5 m-AS.
► Use a special suction sleeve for connecting
the PLANEX.
► Use closing slide CT-VS between the intake
opening [1-1] and suction hose.
► Attach the tool holder.
► Always use with a disposal bag!
7

Settings

7.1
Adjusting the suction power
► at the rotary knob [1-9].
7.2
Temperature cut-out
A temperature cut-out switches the mobile dust
extractor off when it reaches a critical tempera­
ture to prevent overheating.
► Switch off the mobile dust extractor, allow
to cool for about 5 minutes then switch on
again.
Not possible to switch on: contact Festool
service workshop.
7.3
AUTOClean - Cleaning the main filter
(only versions with AutoClean)
Only in conjunction with disposal bag
(compliance with dust class 'L'). Not suit­
able for wet extraction!
Automatic cleaning
Adjust the frequency using the rotary
knob [1-7].
Only CTL 36 E AC-LHS / CTL 36 E AC-RENOFIX:
switch on using the rotary knob [1-7].
Manual cleaning
Turn the switch [1-8] to the AC symbol.
Full manual cleaning
► Cover the end of the nozzle or suction hose
with your hand or closing slide CT-VS
(497926) for 2 seconds.
► Turn the switch [1-8] to the AC symbol.
8

Working

8.1
Handling
Hose holder: After finishing work, you can feed
the suction hose through the opening [8-2] and
place it in the hose holder.
SysDoc Systainer storage area: A Systainer can
be fastened to the storage area with the four
slides or the T-Loc lock [8-1].
8.2
Extracting dry materials
CAUTION
Hazardous dust
Damage to the respiratory passage
► Always use a filter or disposal bag!
When extracting dust that exceeds the
permitted limit values, only extract from
a single machine (electric or air tool).
Observe the following when extracting dust
generated by operating electric power tools:
Ensure there is adequate ventilation! Observe
regional regulations!
Limit values: exhaust air max. 50% of the clear
air volume
Formula: room volume V
8.3
Extracting wet materials/liquids
Remove the filter or disposal bag!
Recommendation: use special wet filter
(NF-CT).
The dust extractor stops automatically when
the maximum level is reached.
After wet extraction, allow the main filter to dry!
CAUTION
Escaping foam and fluids
► Switch off and empty the machine immedi­
ately.
8.4
After finishing work
► Only versions with AutoClean: Clean the
main filter automatically or manually (see
chapter
7.3
).
► Switch off the mobile dust extractor and
pull out the mains plug.
► Wind up the mains power cable.
► Empty the dirt trap.
► Place the mobile dust extractor in a dry
room inaccessible to unauthorised users.