The use of extension cables in Zone 22 is
not permitted.
CAUTION
Risk of injury from tools starting up unex
pectedly
► Before setting the switch to the "AUTO" or
"MAN" position, make sure that the con
nected tool is switched off.
The switch [1-9] serves as an on/off switch.
Switch position "0"
Appliance socket [1-11] is disconnected from
the power, mobile dust extractor is switched
off.
"MAN" switch position
Appliance socket [1-11] is connected to the
power, the mobile dust extractor starts.
"Auto" switch position
Appliance socket [1-11] is connected to the
power, the mobile dust extractor starts when
the connected tool is switched on.
7
Settings
7.1
Adjusting the hose diameter
► Adjust the hose diameter adjuster [1-10] to
match the diameter of the connected hose.
The monitoring devices will measure
the air speed in the extractor hose
correctly as a result (see chap
ter Volumetric flow monitoring).
7.2
Connecting electric power tools
WARNING
Risk of explosion, risk of injury
► Do not use the appliance's socket in zone
22.
► Observe the maximum appliance socket
connected load (see chapter "Technical da
ta")
► Switch off the electric power tool.
► Connect the electric power tool to the appli
ance socket [1-11].
7.3
Connecting pneumatic tools
WARNING
Risk of injury
► Switch off the air tool.
With the compressed air module [1-3], the au
tomatic switch-on function for the mobile dust
extractor also works in conjunction with air
tools.
We also recommend installing the VE service
unit (495886). The service unit filters and lubri
cates the compressed air and enables an ad
justment of the air pressure. An IAS adapter
(454757) is available to connect Festool air tools
to the IAS system.
The operating pressure of the tool must be 6
bar for the automatic switch-on unit to function
correctly.
7.4
Connecting the energy box
The connection for the energy box (EAA) [1-4]
allows you to connect the mobile dust extractor
with the EAA in order to couple the automatic
switch-on unit on the mobile dust extractor with
the equivalent unit on the EAA.
7.5
Adjusting the suction power
► Use the rotary knob .
7.6
Applying the brake
Folding out the black brake lever [1-15] pre
vents the mobile dust extractor from rolling. To
achieve this, lift the front end of the mobile dust
extractor slightly and push the black brake lev
er downwards until it latches into place. Push
the green lever again to release.
7.7
Temperature cut-out
A temperature cut-out switches the mobile dust
extractor off when it reaches a critical tempera
ture to prevent overheating.
► A temperature cut-out switches the mobile
dust extractor off when it reaches a critical
temperature to prevent overheating.
► Switch off the mobile dust extractor and al
low to cool for approx. 5 minutes.
► Change the cooling air filter if necessary
(see chapter
9.2
If the mobile dust extractor will not
switch on again, please contact a Fes
tool service workshop.
7.8
Changing the filter bag (SC-FIS-CT 48)
Removing the filter bag [4]
► Open the locking clips [2-2] and remove the
top section of the machine [2-1].
► Remove the filter bag.
► Dispose of the used filter bag in accordance
with statutory regulations.
).
English
17