Ordinary Maintenance - Volpi OLYTECH mondial 755SP Manuel D'utilisation Et De Maintenance

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 80
Fix the new tine in the support Y and then in the housing P, pushing it down eventually using a hammer.
Screw the locking nut up to the limit.
8.

ORDINARY MAINTENANCE

755SP-L-XL 845SP-L-XL 855SP-L-XL 865SP-L-XL
Codes
MAINTENCANCE
Maintenance has to be carried on by qualified personnel, following the instructions of this manual and
using only original spare parts. User has to follow all the applicable safety laws, using as necessary the
right protective equipment.
IMPORTANT : Every 50 working hours, the internal mechanisms of the head have to be
lubricated with grease for high temperatures. The points have to be lubricated according to
the picture F.
Follow the instructions in fig. F for the grease input.
Rotate the head in order to have access to the rear part (fig. F.1) and identify the two holes V. Unscrew
the two screws W, as indicated in fig. F.2. Using one needleless syringe, as indicated in fig. F.3, put the
grease inside using the holes V. Reassemble the screws and tighten them down. To prevent the screws
from loosening due to vibrations, it is recommended to use thread lockers.
LONG TERM MAINTENANCE
In case of long lasting inactivity periods, the machine has to be carefully cleaned and then protected
from dust and humidity in a dry place clear from direct sun and freeze. The battery shall not be
connected with the machine as is it is not in use. It shall be stored with full charge and re-charged every
6 months.
CHECKS
COMPONENT
Clamps and connectors
Power cable
Tines
ANOMALIES
ANOMALIES
LED SIGNALS
By pressing the
start button the
Led OFF
motor does not
The led flashes every 4 seconds for 5 times, then
turn on.
it flashes continuously
The led flashes every 4 seconds for 5 times, then
it flashes continuously
Led OFF
Led OFF
Led flashes
All the LEDs of the power supply are off.
LEDs are regularly ON
LEDs are regularly ON
ALARM red light ON
ALARM red light ON (single impulse)
ALARM red light ON (multiple impulses)
COMPANY WITH QUALITY SYSTEM
MANAGEMENT CERTIFIED BY ICIM
ACTION
Check the integrity and efficiency of the
contacts
Check that the cable is not twisted
Check the integrity and locking
Tel. +39 0376 76009 Fax +39 0376 76408 www.volpioriginale.it
= ISO 9001 =
Rif. Fig. F
FREQUENCY
Every day
Every day
Every day
CAUSE
Damaged clamps or connectors
Damaged external cables
Damaged internal cable
Damaged motor
Blown fuse (handle)
Completely empty battery
Too low battery voltage
Damaged clamps or connectors
Interrupted fuse
Damaged electronic power supply
Damaged cables
Damaged motor
Empty battery
Low battery
Anomaly
Davide e Luigi Volpi S.p.A.
Via San Rocco, 10 – 46040 Casalromano (MN) – Italia
SOLUTION
Replace
Replace
Replace
Replace
Replace
Replace or recharge
Recharge
Replace
Replace
Replace
Replace
Replace
Replace or recharge
Recharge
Contact the service
point
43