MFP 100E - MFP 200E
Models
Dimension A
MFP 100E
560 mm
MFP 150E
630 mm
MFP 200E
800 mm
During assembly, the safety area must be complied
with according to the current installation regulations.
The socket or supply connection socket must be
accessible after installation.
Make sure that the inflow and outflow of air at the top
and bottom of the device are unimpeded
NOTE
Installation on wooden walls is permissible.
Wall mounting
ATTENTION!
The original wall bracket supplied on the rear
of the device must be used!
NOTE
Look out for electric cables or pipework in the wall
when drilling.
Remove the wall bracket from
the rear side of the device. To
do this, press both springs
down.
Drill the fastening holes.
Screw the wall bracket
securely to the wall.
Hook the device in the bottom slots of the wall
bracket.
Fold the device up and engage in the springs to
lock.
3. Electrical connection
The voltage specified on the type plate must match
the line voltage.
The cable must not be in contact with the casing.
It is recommended that a separate circuit be provided
for the power supply.
www.dimplex.eu
The device must only be installed and repaired by a
qualified electrician in accordance with the applicable
Dimension B
safety regulations. Heating device must be earthed!
Connection may only take place on securely routed
340 mm
cables!
410 mm
A disconnecting device with a contact opening of at
least 3 mm at each pole (e.g. circuit breaker) must be
580 mm
provided in the permanently installed wiring.
4. Overload protector
For your safety, the heating device is equipped with
an overload protector. If the air circulation is
interrupted (e.g. due to the air grille being covered or
closed), the device switches off automatically.
.
In this case, the power supply to the heating device
should be disconnected for a few minutes (switch off
the fuse) to allow the device to cool down sufficiently.
Before recommissioning the device, remove the
reasons for the overload protector being triggered.
5. Cleaning
The device must be disconnected from the mains and
allowed to cool down before cleaning and
maintenance. Clean the outside of the device using a
soft, damp cloth. Do not use scouring powder or
furniture polish as this may damage the surface. Dust
which gathers inside the device can be removed from
the outside using a vacuum cleaner.
6.
If there is a malfunction on the heater message Err is
displayed.
Display
Err1
Err2
Err3
Err4
Err9
Err10
After eliminating the error delete the error message.
2208/D
Errors
Meaning
Temperature sen-
sor defect.
Window detection
operated.
Heating device
too hot.
Ambient tempera-
ture exceeded.
Loss of time.
Heating element
defective.
Press button ENTER for ten seconds. Display Err
disappears.
The heater is ready for operation.
English
Measurements
Contact our service
Close window.
Delete error message.
If necessary deactivate
the function, see sec-
tion 11.6
See chapter 4.
Delete error message.
Notify the factory after-
sales service.
Delete error message.
Re-enter time.
Notify the factory after-
sales service.
EN-3