4 CONFIGURATION

4.4.5. Overfill correction

The 8025 Dose Controller has a jet correction facility. It memorises the fluid quantity which
continues to flow after the closure of the valve so that it can be deducted from the following
dosage. In this sub-menu the user enables or disables the jet correction facility.
ENTER
OVERF. N°
OVERFILL
ENTER
ALARM
OVERF. Y
4.4.6 Alarm
The user can set the time delay before the alarm is triggered by using this sub-menu. The
alarm display prompt is « ALARME ». This alarm data prompt is also available on tag strip
terminal N°. 5 (transistor output, open collector) and on Relay N° 2 if this relay has been
configured as an alarm relay (see next paragraph).
For the conditions required to trigger the alarm, see Section 5.
Range of adjustment: between 0 and 180 seconds.
ENTER
DEL =
000
ALARM
0......9
ENTER
DEL = 015
RELAY

4.4.7. Relays

There are two relays in the unit:
- Relay 1 only controls the opening of the main valve (high flow rate). A time delay before
activation may be fixed and the operating polarity may be inverted; the user also has the
facility of setting the percentage of the dosage quantity to be delivered through the main
valve (high flow rate). This latter facility implies that Relay 2 controls an auxiliary valve (low
flow rate) in order to provide the remainder of the quantity which was initially set.
- Relay 2 can be configured for three different functions: Alarm, end of dosage and control
of an auxiliary valve. In each configuration the operating polarity can be inverted.
E-29-
8025-BATCH-**