The units are suitable for discharging clean, clear water containing solids up to the maximum size specified in the
technical data.
The typical areas of use of a deep-well pumps include: Irrigation of gardens and garden beds, domestic water
supply with grey water from wells, cisterns and reservoir tanks, the operation of irrigation systems, cleaning of
terraces and sidewalks, discharge of water from great depths water extraction from great depths.
Deep-well pumps from T.I.P. are suitable for permanent or temporary installations.
This product is intended for private use in the home area and not for commercial or industrial purposes or for
continuous circulating.
The device is not suitable for use in swimming pools or for the supply of drinking water.
The pump is not suited to discharge saltwater, faeces, inflammable, etching, explosive or
other hazardous liquids. Please observe the max. temperature of the liquids to be discharged
stated in the technical data.
Inside the pump, lubricants are used which may contaminate the liquids being discharged in
case of any improper operation or damage of the device. The lubricants used are biologically
degradable and non-hazardous to health.
4. Scope of delivery
The scope of the delivery of this product includes:
One pump with connection cable, one lowering rope, one operating manual.
Please verify that the scope of delivery is complete. Depending on the purpose of the application, additional
accessories may be necessary (please refer to the chapters titled "Installation" and "How to order spare parts").
If possible, keep the packing until the warranty period has expired. Please dispose of the packing materials in an
environmental-friendly manner.
5. Installation
5.1.
General installation information
During the entire process of installation, the device must not be connected to the electrical
mains.
The pump and the entire connection system have to be protected from frost.
Please also note the illustrations which are located in the text and also as an annex at the end of these operating
instructions. The figures, which are shown in brackets in the statements below, refer to fig. 5 at the end of the
operating instructions.
All connection lines have to be perfectly tight since leaking lines may affect the performance of the pump and
cause considerable damage. If required, please use a suitable sealant to make the installation airtight.
Avoid excessive force when tightening the screwed connections, which can lead to damage. When laying the
connection pipes, you should make sure that the pump is not exposed to any form of weight, vibration or tension.
Moreover, the connection lines must not contain any kinks or an adverse slope.
5.2.
Installation of the pressure line
The pressure line conveys the liquids to be discharged from the pump to the point of withdrawal. To avoid
dynamic flow losses, one should use a pressure line having at least the same diameter as the pressure port (5) of
the pump.
The pressure line to be used for this application should be a suitable flexible hose.
Rigid pipes have proven to be the ideal pressure line for use in a permanent installation.
The pump is equipped with an integrated check valve (non-return valve). It will prevent liquid from flowing back
from the pressure line into the pump after the pump is shut down and protect the unit from being damaged by
pressure peaks.
The pressure line is to be installed to the pressure port (5) of the pump.
3
11