Télécharger Imprimer la page

Dimplex SI 75TU Instructions D'installation Et D'utilisation page 31

Publicité

Les langues disponibles

Les langues disponibles

SI 50TU - SI 75TU
7
Complies with the European safety regulations
8
Additional model features
8.1
Water in device is protected against freezing
8.2
Max. operating overpressure (heat source/heat sink)
9
Heat output / COP
9.1
Heat output / coefficient of performance (COP)
1. If necessary, the operating range can be extended to a brine inlet temperature of -10 °C. In this case, the minimum brine concentration must be adjusted to 30%. (Freezing
temperature -17 °C)
For brine inlet temperatures of -10 °C to -5 °C, flow temperature increasing from 50 °C to 60 °C.
For brine inlet temperatures of -5 °C to 0°C, flow temperature increasing from 60 °C to 62 °C.
2. Operation is possible at brine inlet temperatures of up to +35 °C. For brine inlet temperatures of +25 °C to 35 °C, flow temperature decreasing from 62 °C to 58 °C.
3. The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation at 55 °C flow temperature.
The specified sound pressure level represents the free sound area level. The measured value can deviate by up to 16 dB(A), depending on the installation location.
4. Note that additional space is required for pipe connections, operation and maintenance.
5. These data indicate the size and capacity of the system according to EN 14511. For an analysis of the economic and energy efficiency of the system, the bivalence point and
regulation should be taken into consideration. These specifications can only be achieved with clean heat exchangers. Information on maintenance, commissioning and oper-
ation can be found in the respective sections of the installation and operating instructions. The specified values, e.g. B0 / W55, have the following meaning: Heat source tem-
perature 0 °C and heating water flow temperature 55 °C.
6. See CE declaration of conformity
7. The heat circulating pump and the heat pump manager must always be ready for operation.
8. The coefficients of performance are valid with the circulating pumps included in the scope of supply.
www.gdts.one
7
bar
5 8
Performance level
at B-5 / W45
kW / ---
at B0 / W55
kW / ---
at B0 / W45
kW / ---
at B0 / W35
kW / ---
452237.66.50 · FD 9912
6
Yes
3.0
EN 14511
1
2
21.9 / 3.6
41.3 / 3.3
23.1 / 2.9
44.1 / 2.8
25.1 / 4.0
47.8 / 3.7
27.4 / 5.4
52.0 / 5.0
English
6
Yes
3.0
EN 14511
1
2
32.2 / 3.9
60.7 / 3.2
34.9 / 3.1
67.3 / 3.0
36.7 / 3.9
70.2 / 3.7
37.9 / 5.0
73.5 / 4.8
EN-13

Publicité

loading

Ce manuel est également adapté pour:

Si 50tu