Messages
15 .1 Status messages (Handy 200 ControlPro)
‰ An error code is displayed in the 7 seg-
ment display in event of an error.
‰ The status message can be deleted by
pressing the Electrode/TIG button.
Code
Note
H06
EEProm write/read
error
15 .2 Error messages (Handy 200 ControlPro)
‰ An error code is displayed in the 7-seg-
ment display in the event of a malfunc-
tion. Press the Menu button to display the
Sub-Code.
Code
Error
E01
Thermal overload
E02
Power section
E03
Current sensor
E06
Primary current
transformer
E07
Supply voltage 15V Fault internal supply voltage
E13
Control panel
E14
Control panel
- 38 -
Cause
Communication with EE-
Prom faulty
Cause
Duty cycle exceeded
Fan defective
Power section start-up faulty
Current sensor defective
Current difference between
transformer and sensor is too
high
Component group control panel
faulty
Component group control panel
faulty
After the message has been out-
i
put, the machine will only function
to a limited extent; the error must
be corrected as quickly as possi-
ble.
Possible remedy
Switch machine off and on
again, execute master reset
As long as there is an error code
i
on display welding is not possible.
Possible remedy
Allow switched-on machine
to cool down for a few mi-
nutes.
Check the fan: Switch unit
on and off, fan must start up
for a short period,
Inform Service
Inform Service
Inform Service
Inform Service
Inform Service
Inform Service