Before operation
12
Before operation
6
Abb. 10: Transportation belt
Transportation belt
6
12 .1 Fasten transportation belt
 Thread the transportation belt into the
welding machine and plastic slides. See
sequence of the number in the picture.
12 .2 Connecting the ground cable
When you select the workplace, pay at-
tention to the proper connection of ground
cable and ground clamp.
The ground clamp shall be attached to the
workpiece or the welding table in a way that
the clamp is fixed onto a blank, conductive
area. It shall be located right next to the weld
point to avoid an uncontrolled backflow of
the welding current through machine com-
ponents, ball bear-ings, electric boards and
circuits.
10.15
27
Plastic slides
27
L
(R)
1
L
(S)
2
L
(T)
3
N(MP)
PE
1
1
Abb. 11: Ground cable
Do not place the ground clamp on the wel-
ding machine or gas cylinder, otherwise wel-
ding current is conducted via the protective
conductors and will destroy them.
Never put the ground clamp loose onto the
workpiece. Connect the clamp properly to
the welding table or the workpiece.
2
- 31 -