Télécharger Imprimer la page

Kübler CODIX 924-6 Mode D'emploi page 45

Publicité

Les langues disponibles
  • FR

Les langues disponibles

All manuals and user guides at all-guides.com
HTL level
AC supply
DC supply 12V
DC supply 24V
Add
Sub
55 kHz
Cnt.Dir
Up.Dn
20 kHz
Up.Up
Quad
28 kHz
Quad 2
10 kHz
Quad 4
A/B
(A-B)/A
5V level
typ. Low
1,0 V
typ. High
4,0 V
Add
Sub
Cnt.Dir
9 kHz
Up.Dn
9 kHz
Up.Up
Quad
9 kHz
Quad 2
Quad 4
9 kHz
A/B
(A-B)/A
www.kuebler.com
typ. Low
2,5 V
typ. High
22 V
typ. Low
2 V
typ. High
10 V
typ. Low
2,5 V
typ. High
22 V
AddAr
AddTot
SubAr
AddBat
1,5 kHz
1,5 kHz
1,5 kHz
1,5 kHz
0,7 kHz
0,7 kHz
0,7 kHz
0,7 kHz
29 kHz
AddAr
AddTot
SubAr
AddBat
1,3 kHz
1,6 kHz
1,3 kHz
1,6 kHz
0,5 kHz
0,7 kHz
0,5 kHz
0,7 kHz
9 kHz
HTL level
AC supply
DC supply 12V
DC supply 24V
5V level
HTL
65 kHz
A
A – B
A + B
59 kHz
A / B
(A-B)/A
Quad
30 kHz
NOTE: Switching levels of the input
Switching levels with AC supply:
HTL level
Low:
High:
5V level
Low:
High:
Switching levels with DC supply:
HTL level
Low:
High:
5V level
Low:
High:
typ. Low
2,5 V
typ. High
22 V
typ. Low
2 V
typ. High
10 V
typ. Low
2,5 V
typ. High
22 V
typ. Low
1,0 V
typ. High
4,0 V
5V
9 kHz
9 kHz
9 kHz
0 .. 4 VDC
12 .. 30 VDC
0 .. 2VDC
3,5 .. 30 VDC
0 .. 0,2 x UB
0,6 x UB .. 30 VDC
0 .. 2 VDC
3,5 .. 30 VDC
Page 19

Publicité

loading