Display
LCD positive or negative,
backlit
2 x 6-digit
Digit height
upper line
lower line
special characters
Overload/
Blinking, 1 s
Underload
Counter loses up to 1 decade
no pulses
Data retention
> 10 years, EEPROM
Operation
8 keys
Count frequency max. 50 kHz (see section 13.
frequencies typ.)
Response time of the outputs:
Optocouplers
Add/Sub
With automatic repeat
A/B ; (A-B)/A
Frequency range
0.01 Hz to 50 kHz (see
section 13. frequencies typ.)
Measuring
76.3 Hz Time interval
principle
(period measurement)
> 76.3 Hz Gate time
Gate time approx.13.1 ms
Measuring error
< 0.1% per channel
Response time of the outputs:
1-channel operation < 100 ms @ 40 kHz
<160 ms @ 50 kHz
2-channel operation < 190 ms @ 40 kHz
< 290 ms @ 50 kHz
Seconds
Minutes
Hours
h.min.s
Min. time measurable
Measuring error
Response time of the outputs:
Optocoupler
Polarity:
programmable NPN/PNP
for all inputs in common
Input resistance
5 k
Pulse shape
any
www.kuebler.com
9 mm
7 mm
2 mm
< 4 ms
< 1 ms
< 28 ms
0.001 s ... 999 999 s
0.001 min ... 999 999 min
0.001 h .. 999 999 h
00h.00min.01s ...
99h.59min.59s
500 s
< 50 ppm
< 4 ms
Switching level with AC supply:
HTL level
Low:
High:
5V level
Low:
High:
Switching level with DC supply:
HTL level
Low:
High:
5V level
Low:
High:
Minimum pulse length of the Reset input:
Minimum pulse length of the Control inputs:10 ms
Outputs 1 to 6
NPN optocoupler
Switching capacity
U
for IC = 10 mA:
CESAT
U
for IC = 5 mA:
CESAT
Outputs 3, 4, 5 and 6 have a common emitter
AC supply:
90 ... 260 V AC / max. 8 VA
50/ 60 Hz
ext. fuse protection: T 0.1 A
DC supply:
10 ... 30 V DC/ max. 1.5 W
reverse polarity protection
ext. fuse protection T 0.2 A
24 V DC ±15%, 80 mA
AC supply:
DC supply:
max. 80 mA, external voltage
supply is connected through
Operating temperature: -20°C .. +65°C
Storage temperature:
Relative humidity: RH. 93% at +40°C,
Altitude:
Noise immunity:
EN61000-6-2
with shielded signal and
control cables
Noise emission:
EN55011 Class B
Design to:
EN61010 Part 1
Protection Class:
Class 2
Application area:
Soiling Level 2
0 ... 4 VDC
12 ... 30 VDC
0 ... 2VDC
3,5 ... 30 VDC
0 ... 0,2 x UB
0,6 x UB ... 30 VDC
0 ... 2 VDC
3,5 ... 30 VDC
1 ms
30 VDC/10 mA
max. 2.0 V
max. 0.4 V
-25°C .. +75°C
non-condensing
to 2000 m