Duration of timed signal of
Output 1, programmable from
00.01 to 99.99 s.
Timed output is post-triggered.
7.8.6.7 Submenu for Preset 3, 4, 5 and 6
Only preset 3 is represented here.
Submenu for Preset 3 [to 6]
ADD mode output operations:
permanent signal at Output 3 [to
6], becomes active when count >
preset 3 [to 6]
SUB mode output operations:
permanent signal at Output 3 [to
6], becomes active when count <
preset 3 [to 6]
ADD mode output operations:
permanent signal at Output 3 [to
6], becomes passive when count
> preset 3 [to 6]
SUB mode output operations:
permanent signal at Output 3 [to
6], becomes passive when count
< preset 3 [to 6]
ADD mode output operations:
timed signal at Output 3 [to 6],
becomes active when count >
preset 3 [to 6]. (Activation only in
positive direction)
SUB mode output operations:
timed signal at Output 3 [to 6],
becomes active when count <
preset 3 [to 6]. (Activation only in
negative direction)
ADD mode output operations:
timed signal at Output 3 [to 6],
becomes passive when count >
preset 3 [to 6]. (Deactivation only
in positive direction)
SUB mode output operations:
timed signal at Output 3 [to 6],
becomes passive when count <
preset 3 [to 6]. (Deactivation only
in negative direction).
ADD mode output operations:
timed signal at Output 3 [to 6],
becomes active with positive
direction and when count >
preset 3 [to 6] and subsequently
with negative direction and when
count < preset 3 [to 6]
SUB mode output operations:
timed signal at Output 3 [to 6],
becomes active with negative
www.kuebler.com
direction and when count <
preset 3 [to 6] and subsequently
with positive direction and when
count > preset 3 [to 6]
ADD mode output operations:
timed signal at Output 3 [to 6],
becomes passive with positive
direction and when count >
preset 3 [to 6] and subsequently
with negative direction and when
count < preset 3 [to 6]
SUB mode output operations:
timed signal at Output 3 [to 6],
becomes passive with negative
direction and when count <
preset 3 [to 6] and subsequently
with positive direction and when
count > preset 3 [to 6]
Duration of timed signal of
Output 1, programmable from
00.01 to 99.99 s.
Timed output is post-triggered.
Active:
Optocouplers are activated when
the preset value is reached.
Passive:
Optocoupler disabled when the
preset value is reached.
7.9.1 Setting via Decade Keys
In operating mode Preset 2 will be displayed in the
lower line, excepted for the output operations
AddBat and AddTot.
Press the Prog/Mode key until
the preset to be changed is
displayed -
,
Press any decade key
Õ
Display switches to the editor mode
Set the desired preset value
using the decade keys
Press the Prog/Mode key to
confirm the value and save it
Õ
Display switches to the editor mode of the
next preset.
,
,
,
or
.