FAULT
There is water on the
floor.
The lights don't
work.
If after all the above-mentioned checks the problem with your ICM remains, contact the customer
service department of your supplier and provide the following information:
Type of ICM
Serial number of the ICM
Brief description of the problem / observation
8. First Aid
In case of accident, proceed to the following:
ACCIDENT
Inhalation of refrigerant
Contact with eyes
Contact with skin
9. Disposal of the Unit
For detailed information regarding the recycling of this product, please contact your local city office,
your waste disposal service or the manufacturer through its service agent. By ensuring this product is
disposed of properly, you will help prevent potential negative consequences for the environment and
human health, which could otherwise incur by this product's inappropriate disposal.
10. Recycling Information
1.
Based on the objectives of environmental policy according to the European Community (EC)
directives of Waste Electrical and Electronic Equipment (WEEE)
and improve the quality of the environment, protect human health and utilize natural resources
prudently and rationally, as an end user, you are kindly requested to do the following:
*
References
Waste Electrical and Electronic Equipment (WEEE) European Community (EC) Directive Nr. 2002/96/EC
20
POSSIBLE REASONS
The drainage hole for the
condensate water is blocked.
There is a leakage in the tray.
The lighting or the transformer are
out of order
IMMEDIATE ACTION
Take deep breaths of clean air. If irritation persists, contact a
doctor.
Wash your eyes thoroughly with plenty of water for at least 15 minutes
and then consult a doctor
Wash immediately with water.
HANDLING
Unblock the drainage hole.
Call a Service technician.
Call a Service technician.
*