Télécharger Imprimer la page

FRIGOGLASS Super 800 HC Manuel D'utilisation page 19

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 83
If the ICM is not functioning properly or is out of order, please check the following before calling the
authorized service provider:
FAULT
The ICM does not
work.
The ICM sometimes
makes noise.
UNPLUG THE COOLER PRIOR TO ANY MAINTENANCE OR SERVICE
OPERATIONS. REMOVE THE PLUG AND MAKE SURE THAT THE
OPERATOR CAN CHECK FROM ANY OF THE POINTS WHICH THEY
HAVE ACCESS THAT THE CABLE IS UNPLUGGED.
After maintenance operations, make sure that the grounding
connections are in place before assembling the covers. Make sure
you use the same fastening components and covers.
If any electrical components need to be replaced, use only the
identical components in the spare part list supplied by the technical
service department of Frigoglass.
Keep the glass door on the back side of the cooler closed during
maintenance. The appliance will not stand stable when the
compressor is disassembled. If the compressor needs to be
replaced, use adequate support on the front side of the cooler.
After maintenance operations make sure that the strain relief, which
supports the supply cord, is assembled properly.
POSSIBLE REASONS
Power cord not plugged in.
No power coming through the
socket.
The ICM has recently been reloaded
with warm products. It takes 8-16
hours to cool them down.
The ICM is loaded in such a way that
the air circulation in the interior is
getting blocked.
The door does not seal properly.
Leakage in the cooling system.
For this particular ice cold
merchandiser, a powerful
mechanism is needed and
consequently a certain amount of
noise cannot be avoided.
Intense metallic noise.
Inclined or curved floor.
HANDLING
Plug it in.
Check for fuse/MCB on the mains.
Preferably, reload the ICM before night
closing.
Load the ICM according to the
standards you have been provided
with by the company.
Repair the doors for proper closing
(this type of repair should be
performed by an authorised
technician).
Repair the leakage (This type of repair
should be performed by an authorized
technician).
Ice Cold Merchandisers are of
dynamic type, according to the
specifications that the company is
offering.
Call a Service technician.
Level the ICM properly by adjusting its
feet. Placing a spirit level on the top of
the ICM will assist you in leveling it.
ENG