Display interface
The temperature is displayed in three digits.
Information for the operation is displayed with 3 different figures on the left side
of the display. These are as follows;
- Compressor on
Alarms are indicated with a bell icon and an alarm code on the display.
Functions of the buttons:
: Up/ES button:
Increase set point values.
Activate/de-activate the energy saving mode (night mode) manually by pressing the button for 3
seconds.
The controller is set to switch automatically to night mode when not in use.
: Down/Defrost button:
Decrease set point values.
By pushing at the keypad for at least 0.5sec the light status will be toggled
: Set/Mute button:
Mute the buzzer when an alarm is active.
Alarm code display
E0: Regulation probe fault
E1: Evaporator probe fault (if available)
dF: Changed to regulation probe temperature in Defrost
dor: Door open time-out
E3: Refrigerant System Failure Alarm
EnS: Changed to reg. Probe temp. in Saving mode
For more detailed information and technical specs please refer to the Carel Easy user manual.
- Fan motor on
-Defrost in progress
Up / ES button
Set / Mute button
Down / Light button
ENG