Disconnection Detection Settings - Evolu7 Link Guide D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Settings:【74】【X】【#】
Siren Prompt Setting
In arm or disarm, external siren prompt arm or disarm
In setup status, press[75] on the keypad, then enter[0/1], finally
press [#]; Host make a long beep. A "setting completed" voice
prompt appears. Factory settings: [0]: disable alarm prompt.
Operating method
Example: Detailed operating of sound on
Operation:【75】【1】【#】
Disconnection detection
In Settings, first enter address code [78], select [0/1] to check
whether to enable or disable disconnection alarm and press [#] to
confirm; voice prompts: set successfully, please enter instruction.
If user alarm host is not connected with phone line, please set this
function as [0] with no alarm detection due to line disconnection.
Factory settings: [0]: no detection due to phone disconnection.
Operation:【78】【X】【#】
alarm.
Out Arm Delayed Time Setting
In setting status, press [79], then select the out arm delayed time
[XX] seconds, finally press [#] to confirm. Voice prompt: setting
completed, please enter instruction. factory default: [30] seconds:
Out arm will be enter the arm status after delayed time 30
seconds.
Operating:【79】【XX】【#】
after delayed.
"1" indicates: inform the alarm receiving center.
"0" indicates: don't inform the alarm receiving center
: 【75】【X】【#】
"1": enable alarm prompt
"0": disable alarm prompt
"1": enable disconnection detection and sound alarm.
"0": disable disconnection detection and sound no
XX indicates: Out arm will be enter the arm status