21. Remove threaded ground lug.
ss01434
22. Feed the L1 (black) [Europe H (brown)] wire into
the L1 [Europe H] terminal slot in the wiring cham-
ber.
23. Feed the L2 (red) [Europe N (blue)] wire into the
L2 [Europe N] terminal slot in the wiring chamber.
24. Attach safety ground wire through the slot on the
ground terminal. Hand-tighten grounding lug.
Note:
See inside of wiring chamber cover for wiring schematic.
25. Tighten terminal screws to 1.2 Nm (10.62 in-lb).
Bosch Automotive Service Solutions Inc.
L2/N
L2/N
ss01443
L1
Installation and Operating Instructions | Power Xpress Charge Station | 15 | en
ss01438
26. Reinstall strain relief.
Note:
Select appropriate orientation of insert to achieve prop-
er clamping for wire size used.
CAUTION: Do not overtighten.
27. Attach the wiring chamber lid with four (4) 3/4-in.
(20-mm) square-drive screws.
28. Apply the self-adhesive chamber lid label.
578987 | REV. A | 15.06.2016