Product Features; Technical Specifications - Bosch Power Xpress Instructions D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

en | 4 | Installation and Operating Instructions | Power Xpress Charge Station

Product Features

Voltage and
240VAC single-phase: L1, L2, and
Wiring
safety ground. •
(120V above
208VAC 3-phase, wye-connected:
ground)
Any 2 phases and safety ground.
240VAC 3-phase, delta-con-
nected: with center tap on one
leg, use only the two phases on
either side of the center tap. The
two phases must both measure
120V AC to ground. Do not use
the third leg (208V "stinger")
Voltage and
230V AC single-phase:
Wiring
LINE, NEUTRAL, and EARTH
(230V above
ground
- Europe)
Current and
Current—Model dependent; see unit
specification label
Frequency
50/60Hz
Cable
Maximum 25 ft (7.6 m) per NEC 625
—Model dependent; see unit specifi-
Length and
cation label (18 ft (5.5 m) typical)
Connector
Thermal switch
Dimensions
14.5 in. (368.3 mm) height × 5.2 in.
(132 mm) width × 4.3 in. (109.2) depth
Weight
Approximately 16 pounds w/25 ft
(7.6 m) cable and coupler
Operating
-40°F to +122°F (-40°C to +50°C)
Temperature
-58°F to +176°F (-50°C to +80°C)
Storage
Temperature
Ratings and
Enclosure Type NEMA 4X –
Agency
indoor/outdoor use, watertight
Approvals
ETL approved to UL and CSA
standards•
CE compliant w/3rd-Party ETL
testing•
FCC Part 15 Class-B compliant
578987 | REV. A | 15.06.2016

Technical Specifications

Output
32A Max, Model Dependent
Amperage
(see output spec. label on side of
Charge Station)
Input
175 VAC – 264 VAC
Voltage
Range
Frequency
50/60Hz
Ground
17.5 mA (20mA Max)
Fault Trip
Level
Ground
50K ohm Max (North American),
Assurance
100K ohm Max (Europe)
Surge
6kV @3000A
Protection
Operating
Up to 95% non-condensing
@1060hPa
Humidity
Operating
-40°F to +122°F (-40°C to +50°C)
Temperature
Storage
-58°F to +176°F (-50°C to +80°C)
Temperature
Ground Fault
Automatic at startup (Firmware con-
Test
trolled)
Ground Fault
4 automatic retries @ 15 min. inter-
Retry
vals (per UL2231-2)–not applicable to
European models
Master Clear
For System Reset
(Overrides Ground Fault Retry and all
other fault conditions)
Power
Green LED
Indication
Charge
Amber (Ready)
Status
Green (Plugged In)
Indicators
Green Flashing (Charging)
Red Flashing (Fault)
Enclosure
NEMA 4X & per UL 50E
Bosch Automotive Service Solutions Inc.