Télécharger Imprimer la page

Dustbane Integra Scrub Manuel De Pièces Et D'opérations page 6

Publicité

Les langues disponibles

Les langues disponibles

• Servicing this machine while still connected to a power source could lead to electrocution or fire. Before performing
machine service or maintenance, disconnect the machine from it's power source. Operating this machine with a damaged
power cord could lead to electrocution or fire. Cord should remain clear of moving parts during operation. Never use the
cord to navigate the machine.
Troubleshooting
Problem
Machine will not start
Runs erratically
Fuse/Circuit Breaker Trips
Machine pulls hard to one side
Note: The rubber isolators on the EBG
are considered wear items. It is
recommended to replace the entire
set of all four isolators once per year
(or sooner under heavy use) to prevent
failure and damage to the machine.
Machine is noticeably louder than it
was when originally purchased
6
All manuals and user guides at all-guides.com
Cause
Not Connected to power source
Voltage too low
Defective switch
Low voltage from excessive length
or
undersized extension cord
Defective start switch
Defective motor low voltage
Low voltage
Low input volts
Worn Pad
Rubber isolators are worn out
Rubber isolators worn
Removable weights
not secured
Action
Check power source connection and
lighted plug
Have electrician check outlet
Contact Dustbane dealer
Use 10 gauge extension cord
Not more than 25' long
Contact Dustbane dealer
Contact Dustbane dealer
Allow the motor to cool. The circuit
breaker is a red button on the side of the
motor that will reset when pressed.
Eliminate extension cord.
Locate power cord closer to work site.
Have voltage checked by electrician.
Rotate pad 180 degrees
Flip pad over
Replace Pad
Replace isolators
Replace isolators
Tighten star knobs on removable
weights

Publicité

loading