Télécharger Imprimer la page

Oase InScenio EGC Notice D'emploi page 47

Masquer les pouces Voir aussi pour InScenio EGC:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 63
Current water temperature in °C
Display only.
Number of cleaning cycles in the past 24 hours
The total of the automatic and time-dependent cleaning cycles is displayed.
The value is saved in the filter control system.
N O T E :
The filter system self-diagnostics monitor automatic cleaning. The test is carried out contin-
uously in a 2 × 24 hour cycle. The test is only active from a water temperature >12 °C.
Very different values may be indicated due to the test.
First 24 hour cycle
If at least one automatic cleaning process is detected, the cycle is repeated after the clean-
ing process has finished.
If no automatic cleaning process is detected, the second 24 hour cycle starts once the first
has finished.
Second 24 hour cycle
The time-dependent cleaning cycle is deactivated. This reduces the number of cleaning cy-
cles.
If at least one automatic cleaning process is detected, the first 24 hour cycle starts again
once the cycle has finished.
If no automatic cleaning process is detected, the system message Er22 is triggered at the
end of the cycle. The time-dependent cleaning cycle starts again.
If an automatic cleaning process is then detected, the first 24 hour cycle starts again. The
system message Er22 is automatically reset.
Total number of cleaning cycles
The total of the automatic, manual and time-dependent cleaning cycles is displayed.
The value is saved in the filter control system.
Manual cleaning
Manually triggered cleaning cycle.
How to proceed:
1. Tap
to start the cycle.
All active cleaning cycles (automatic, time-dependent or manual) are stopped.
2. To cancel the process, tap
again.
- EN -
47

Publicité

loading