Maintenance

Perform the following maintenance procedures to keep your HVLP
spray gun working properly. New parts can be obtained by ordering
the HVLP Gun Repair Kit, part number 0279911.

Adjusting the Packing Nut

If material leaks from around or through the packing nut, readjust the
packing nut.
1. Disconnect the air hose from the air inlet and remove the cup
assembly.
2. Pull the trigger all the way back and hold.
3. Tighten the packing nut using a 3/8 inch wrench until the
needle remains retracted inside the nozzle when you release
the trigger.
4. Loosen the packing nut slowly
until the needle moves freely
back into position in the nozzle.
Once you have adjusted the nut,
reconnect the air hose and the cup
assembly. Squeeze the trigger to see if
the leaking has stopped. If it has not,
make sure the packing nut is as tight as
possible, while allowing the needle to
move freely. If adjusting the packing
nut does not stop the leak, replace the
packing.
Replacing the Needle Packing
and Air Valve Seals
NOTE: Remove the needle packing only when replacing
with a new needle packing. Do not remove the
needle packing for cleaning.
The needle packing and the air valve seals can be
replaced separately. If you are replacing only one of
them, use the appropriate steps from the following
procedures.
A) Removing / Replacing the Packing
1. Separate the gun head from the gun rear (see instructions on
page 3). The needle will remain in the gun head.
2. With the two sections of the gun still separated, remove the
needle.
3. Remove the packing nut using a 3/8 inch wrench.
4. Remove the packing from the packing nut.
Gun head
NOTE: Make sure all of the old packing is removed before
installing the new packing.
5. Place the new packing into the packing hole.
6. Thread the packing nut one turn into the packing hole. Do
not tighten.
7. Replace needle into packing nut.
8. Tighten the packing nut securely using a 3/8 inch wrench,
then loosen the packing nut a quarter turn.
9. Reassemble the gun head into the gun body.
10. Pull the trigger to make certain the needle moves freely. If
the needle sticks, loosen the packing nut. If the packing leaks,
tighten the packing nut.
English
B) Removing the Needle and Housing
Packing Nut
C) Replacing the Air Valve Seals
Packing
Packing nut
6
1. Disconnect the air hose from the air inlet.
2. Separate the gun head from the gun rear (see instructions on
page 3). The needle will remain in the gun head.
3. Loosen the air flow valve nut and remove the air flow
adjustment knob and the air flow valve nut to allow access to
the material flow adjustment housing.
4. Loosen and remove the material flow adjustment housing,
seal, and spring using a wrench.
Air ow
valve nut
Material
Adjustment
Seal and
Housing
spring
5. Insert an 1/8 inch hex wrench into the back of the needle
guide shaft.
6. Hold the trigger bushing with a small pliers and turn the 1/8
inch hex wrench counterclockwise to remove the retaining
nut.
7. Pull the needle guide shaft out of the gun body. Do not lose
the trigger bushing.
Trigger
bushing
1. Remove the old rear air valve seal. It may stay on the end
of the needle guide shaft spring or in the material flow
adjustment housing.
2. Slide the new rear seal into the material adjustment housing.
3. Remove the front seal retaining clip using a snap-ring pliers.
4. Slide the old front air valve seal off of the needle guide shaft.
5. Place the new front air valve seal on the needle guide shaft
with the beveled side facing the gun.
NOTE: Make sure that the new front air valve seal looks like
the one that was just removed.
SIDE VIEW
Front Air Valve Seal
Needle
guide shaft
Beveled Side
© Titan Tool Inc. All rights reserved.