OPERATION GUIDELINES

Remove the cover and put it on the cover holder
vertically. Put items in the basket then put them in
the cleaning tank. Add general purpose
OPTIM 28 (see OPTIM 28 label for specific
1
dispensing instructions) to a level between MIN
and MAX and above the area to be cleaned.
If the unit is turned on without water,
ultrasonic energy will not be absorbed.
This model also has high power. Once
on for over 15 seconds, it may damage the unit
or severely reduce the life of the unit.
Connect the power cord to an outlet
and turn the switch on. LED display
shows 10:00. This is the most
common timer setting.
If the timer needs to be adjusted,
press TIME key for quick timer
settings and/or Reducing key for fine adjustment
2
between 1 to 30 minutes.
Select desired time setting by pressing the
TIME key:
Prolonged cleaning time may result in:
a. Loosening of the screws if used.
b. If items are plated and have existing cracks,
the cracks may become more pronounced.
c. Coating with preexisting damages may
experience more peeling.
Press On/Off button twice to start cleaning.
During cleaning, buzzing sound can be heard
from the cleaning tank, indicating that the
3
cleaning is underway. Closing the lid will reduce
the noise level.
The digital timer will count down to show the
remaining cleaning time. When it displays
00:00, the cleaning cycle stops.
To stop cleaning at any time, press On/Off button
twice.
The unit is equipped with overheat protector.
If the unit has been running for too long,
the green indicator light will change to red,
indicating the unit is under overheat protection.
The unit can not be operated until idling for about
15 to 20 minutes. The red light will change back
to green and the operation can be resumed.