koban KPA-01T Mode D'emploi page 31

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
Function
Frequency
(Auto ranging)
Duty cycle
Input Protection: 1000 V CA rms
Duty cycle sensitivity: 10 Hz to 1 kHz
Sensitivity: > 15 V CA rms
Frequency with jaws (AC current)
Function
Frequency
Duty cycle
Maximum input: 1000 A CA
AC duty cycle sensitivity: 10 Hz to 1 kHz
Sensitivity: > 50 A (600 A range)
Sensitivity: > 500 A (1000 A range)
Function
Range
Temperature
-20 °C ~ +760 °C
- 4 °F ~ +1400 °F
Sensor: Type K Thermal probe
Input protection: 600 V DC or 600 V CA rms
Function
Testing Condition
Forward DCA is approx. 1Ma,
Diode
OPEN CIRCUIT Voltage MAX,
3V
Continuity
Test current MAX. 1,5mA
Input Protection: 600 V CC o 600 V CA rms
Testing condition
10 Hz to 10 kHz
20 % ~ 80 %
Testing Condition
40 Hz to 1 kHz
20 % ~ 80 %
Resolution
0,1/1 °C
0,1/1 °F
Reading
Forward voltage drops of diode
Buzzer makes a long sound, while resistance is
less than (50Q)
CLAMP METER TRMS
Accuracy ±
(% of reading + digits)
± (1 % of rdg + 5 digits)
± (1,5 % of rdg + 10 digits)
Accuracy
± (% of reading + digits)
± (1 % of rdg + 5 digits)
± (1,5 % of rdg ± 10 digits)
Accuracy
(% of reading + digits)
± 3 % of rdg ± 5 °C
± 3 % of rdg ± 9 °F
KPA-01T
31 / 50

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

0767496

Table des Matières