Gas Connection Installation - Empire Comfort Systems Mantis Instructions D'installation

Masquer les pouces Voir aussi pour Mantis:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CAUTION
The gas supply line to the heater must be installed under
conditions which will allow for easy removal of the heater
from its location for servicing of the heater. For fireplace
insert installation, incorporate a loop into the flexible gas
line.
Under no circumstances should the gas supply line to the
appliance be installed in a way that would prevent the appli-
ance from being serviced or inspected.
Figure 35 - Fireplace Mantis
Gas Connection - In-Wall Units
1.
Remove the access plate on the left side of the cabinet by
removing three screws as shown in Figure 36. Put the screws
aside.
2.
Push the factory supplied flexible gas line through the access
hole on the side.
3.
Remove the knockout from the access plate and insert the
flexible gas line through the hole.
4.
Secure the access plate to the cabinet with three screws re-
moved in Step 1.
5.
A plastic push in plug is supplied in the hardware package,
insert the plug into the 1-3/8 inch hole in the back of the fire-
place.
6.
Insert the rubber grommet into the hole in the access plate to
protect the flexible gas line.
31793-3-1015
All manuals and user guides at all-guides.com

GAS CONNECTION INSTALLATION

GAS SUPPLY LINE TO FIREPLACE
1.
Pull the factory installed flexible gas line through the hole in
the back panel. See Figures 35 and 36.
2.
Connect the gas supply line to flexible gas hose. Ensure that
flexible gas hose is not kinked after fitting gas supply line. Any
excess flexible line can be pushed back into the fireplace.
3.
Place rubber grommet that is supplied in hardware packet
over the flexible gas line and secure in the hole in the back of
the appliance.
Figure 36
Gas Connection, Fireplace Mantis In-Wall Units
Page 23

Publicité

Table des Matières
loading