12.1.3 Check communication in RS485
mode
After configuration of RS485, access the camera
directly from the network, without any intervention
on the Ulisse unit at IP level.
If the camera is configured with a DHCP
address and a DHCP server is available on
the network, the IP address is dynamically
assigned. On the DHCP server, check the IP
address currently assigned to the camera.
If the camera is configured with a DHCP
address and there is no DHCP server on line,
the camera could take its IP address from
factory settings (for example, 192.168.1.1),
or a ZeroConf address on subnet
169.254.0.0 /16. Check the user manual of
the camera.
To find the address of the camera in use, use
the specific software tools provided by the
manufacturer of the camera, or the network
analysis tools (e.g. Wireshark).
Using a web browser, open the user Control page of
the camera on the IP address of the camera.
Video streaming should be displayed on screen,
and the Ulisse unit should move when the Pan & Tilt
commands are given.
The PC must be adequately configured,
with an IP address compatible with the
address of the camera (same subnet).
MNVCUPTMAXIR_2104_EN
12.1.4 Alarm status control
To check the status of the alarm lines, you need to
have a CCTV test or a monitor connected to the Video
output (12.1.1 Analogue Video connection, page 46).
Enter the Ulisse unit OSD, giving the SAVE PRESET 95
or AUX 8 ON commands (Pelco-D protocol).
Using the UP/DOWN and ZOOM +/- commands,
insert the following path:
• DIGITAL I/O \ ALARMS \ ALARM STATUS
Check the alarms line status (Fig. 105, page 49).
ALARMS STATE
ALARMS STATE
------------------------
------------------------
ALARM 1
ALARM 1
ALARM 2
ALARM 2
ALARM 3
ALARM 3
ALARM 4
ALARM 4
Fig. 105
The default lines are configured as Normally Open.
CLOSED means an alarm status, while OPEN means
no alarm is detected.
To force inversion of the alarms status, place SW7 of
the second dip-switch (DIP2) to ON.
Check the new line status of the alarms.
CLOSED
CLOSED
CLOSED
CLOSED
CLOSED
CLOSED
CLOSED
CLOSED
49