Télécharger Imprimer la page

Videotec ULISSE MAXI Manuel D'instructions page 40

Masquer les pouces Voir aussi pour ULISSE MAXI:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 130
NTP Server: It is also possible to specify if the device
needs to be synchronised with an external NTP
(Network Time Protocol) server.
• DISABLED: Select this option if you do not wish to
synchronise date and time of the device.
• DHCP: Select this option if you wish to synchronise
the date and time of the device with those of an
NTP server (Network Time Protocol) indicated by
the DHCP server.
• STATIC: Select this option if you wish to
synchronise date and time of the device with those
of the NTP server specified by the static address.
In order for the device to operate correctly,
it is necessary to synchronise it with the
VMS software using a NTP server.
For correct operation of the device it is
necessary to synchronise the camera with
the Pan & Tilt. In order to achieve this
synchronisation, from the web page for
the camera select option NTP from DHCP,
or specify the address 192.0.0.1 as a static
address of the NTP server.
10.1.8 User Configuration page
From menu entry User Configuration it is possible
to manage all users that have access to the device.
Administrator type users can access the complete
configuration of the device. Users such as Operators,
Users and Anonymous have limited access to the
management pages.
Fig. 73
The device can be configured only by users
with administration privileges.
38
10.1.9 Movement Parameters page
From menu entry Movement Parameters it is possible
to control, via web, all Pan & Tilt parameters.
• Offset Pan: The pan & tilt has a mechanically
defined 0° position. The Offset Pan function allows
the definition of a different 0° position using
software.
• Maximum Speed: Sets the maximum manual
speed.
• Speed with Zoom: When enabled, this parameter
automatically slows down the Pan & Tilt speed,
based on the Zoom factor.
• Tilt Factor: Sets the reduction factor of the tilt axis
manual speed.
• Pan Limits: Enables the limits of Pan.
• Pan Start: Sets the start limit of Pan.
• Pan End: Sets the end limit of Pan.
• Tilt Start: Sets the start limit of Tilt.
• Tilt End: Sets the end limit of Tilt.
Fig. 74
MNVCUPTMAXIR_2104_EN

Publicité

loading

Ce manuel est également adapté pour:

Upt1slwan00eUpt3slgan00eUpt2slgan00e