Ingersoll Rand P1IU-A9 Manuel De L'utilisateur page 6

Compresseur d'air portatif
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

MAINTENANCE
WARNING
Unplug the unit, release air pressure from the
tank and allow the unit to cool before
performing maintenance.
WARNING
Wear appropriate personal eye and ear
protection during maintenance.
NOTE
A l l c o m p r e ss ed a ir s ys te ms contain
maintenance parts (e.g. lubricating oil, filters,
separators) which are periodically replaced.
These used parts may be, or may contain,
substances that are regulated and must be
disposed of in accordance with local, state,
and federal laws and regulations.
NOTE
Take note of the positions and locations of
parts during disassembly to make reassembly
easier. The assembly sequences and parts
illustrated may differ for your particular unit.
NOTE
Any service operations not included in this
section should be performed by an authorized
Ingersoll Rand service representative.
ROUTINE MAINTENANCE SCHEDULE
Daily or Before
l
Check lubricant level. Fill as needed.
Each Operation
l
Drain receiver tank condensate. Open the
manual drain valve and collect and dispose
of condensate accordingly.
l
Check for unusual noise and vibration.
l
Ensure guards and covers are securely in
place.
l
Ensure area around compressor is free
from rags, tools, debris, and flammable or
explosive materials.
Weekly/50 Hours
l
Inspect air filter element. Clean or replace
if necessary.
Monthly
l
Inspect for air leaks. Squirt soapy water
around joints during compressor operation
and watch for bubbles.
l
Check tightness of screws and bolts.
Tighten as needed.
l
Clean exterior.
6/100 *
l
Change petroleum lubricant while
crankcase is warm.
12/300 *
l
Change synthetic lubricant while crankcase
is warm.
l
Replace filter element.
* indicates months/operating hours, whichever occurs first.
INTAKE FILTER CLEANING _________________________
Remove the intake filter every 50 hours or once a week and
clean the inside of the intake filter and the filter element with
compressed air. Turn the wing nut counterclockwise to
disassemble intake filter.
http://air.ingersollrand.com
RELEASED 05/Apr/2018 15:16:09 GMT
6
A = Filter Element
WARNING
CAUTION
NOTE
TANK DRAINING __________________________________
Drain both tanks daily or after 4 hours of use. Open drain cock
and tilt compressor to empty accumulated water.
COMPRESSOR PUMP OIL CHANGE _________________
CAUTION
CAUTION
1. Within the first 50 hours of operation, completely replace the oil of
the pumping element. Unfasten the oil drain cap on the casing
cover, drain all the oil, and screw the cap back on.
2. Pour All-Season Select or other approved oil into the hole of the
dipstick to the level indicated on the dipstick. See "Preparation for
Use" section for lubricant recommendations.
3. Check the oil level of the pumping element every 50 hours or
once a week.
4. Change the oil according to the following intervals:
Mineral oil = 100 hours or every 6 months.
All Season Select = 300 hours or every 12 months.
TANK INSPECTION ________________________________
The life of an air receiver tank is dependent upon several factors
including, but not limited to, operating conditions, ambient
environments, and the level of maintenance. The exact effect of
these factors on tank life is difficult to predict; therefore, Ingersoll
Rand recommends that you schedule a certified tank inspection
within the first five years of compressor service. To arrange a
tank inspection, contact the nearest Ingersoll Rand Customer
Center or distributor, or call 1-800-AIR SERV.
If the tank has not been inspected within the first 10 years of
compressor service, the receiver must be taken out of service
until it has passed inspection. Tanks that fail to meet
requirements must be replaced.
WARNING
A
Never clean filter element with a flammable
liquid or solvent.
Do not operate without the intake filter.
Replace the filter element when it becomes
dirty.
Do not operate without lubricant or with
inadequate lubricant. Ingersoll Rand is not
responsible for compressor failure caused by
inadequate lubrication.
Overfilling with oil will cause premature
compressor failure. Do not overfill.
Failure to replace a rusted air receiver tank
could result in air receiver tank rupture or
explosion, which could cause substantial
property damage, severe personal injury, or
death. Never modify or repair tank. Obtain
replacement from service center.