Power Supply Cable Cross-Sections; Actuator Assembly Instructions; Preparing For Assembly - GIESSE RACK MAX 650 Manuel D'utilisation Et D'installation

Masquer les pouces Voir aussi pour RACK MAX 650:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 85
IMPORTANT FOR PRODUCT SAFETY: in synchronized motors with power supply
voltage 24V

Power supply cable cross-sections

9.1.
The table below shows the maximum cable length for the connection of a single actuator.
CABLE CROSS-
SECTION
0.50 mm²
0.75 mm²
1.00 mm²
1.50 mm²
2.50 mm²
4.00 mm²
6.00 mm²

10. ACTUATOR ASSEMBLY INSTRUCTIONS

These instructions are intended for technical and specialized personnel, therefore
basic safety and working techniques are not discussed.
All operations for preparation, assembly and electrical connection must be carried out by
technical and specialized personnel; this will guarantee optimum performance and proper
operation of the actuator. First of all, ensure that the following basic requirements are met:
Before installing the actuator, check that the moving parts of the window or door on
which it is to be installed are in excellent mechanical condition, that they open and
close correctly, and that they are well balanced (where applicable).
The actuator's power must be sufficient to move the window; the limits indicated in
the product technical data table (par. 6) cannot be exceeded. A rough calculation
can be made using the formula provided in paragraph 2.1 of this manual.
Attention: check that the device has the same type of power supply as the one
available at connection, by checking the data on the label attached to the
gearmotor.
Make sure that the actuator has not been damaged during transport, first visually
and then by powering it in one direction and the other.
On bottom-hung windows, there is the risk of injury if the window accidentally falls.
A compass limit stop or an alternative safety system, calculated to prevent the
window from accidentally falling, must be installed.

Preparing for assembly

10.1.
Before starting assembly of the actuator, prepare the following accessory materials,
equipment and tools.
Installation on metal windows: M5 threaded inserts (6 pieces), M5x12 flat headed metric
screws (6 pieces).
Installation on wooden windows: self threading screws for wood Ø4.5 (6 pieces).
, if not used, the G
REEN
24V
~20 m
~30 m
~40 m
~60 m
~100 m
~160 m
~240m
wire must be insulated.
Actuators operating on
110V~
~300 m
~450 m
~600 m
~900 m
~1500 m
~2500 m
~3700 m
41
230V~
~1400 m
~2100 m
~2800 m
~4000 m
~6800 m
~11000 m
~15000 m